Abstract

The dose response of high-sensitivity GafChromic film to photons from 125I seeds for doses up to 200 Gy was established. The optical densities were measured using two types of densitometers: (a) a Macbeth spot densitometer with broadband light spectrum, and (b) an LKB He-Ne laser scanning microdensitometer with red light of wavelength 632.8 nm. The net optical density was found to be a power function of dose with exponents of 0.858 and 0.997, for the Macbeth and LKB densitometers, respectively. Film sensitivity with the LKB densitometer was about double of that with the Macbeth densitometer. The dose measurements were performed using the high-sensitivity GafChromic films for 125I model 6702 seed in solid water phantom. Each film was positioned parallel to the seed's long axis and centered at the seed's transverse axis. Films were exposed at various distances, ranging from contact to 3 cm from the seed center. The radiation dose delivered to the film center varied from 7 to 50 Gy, depending on the distance. The optical density at the film center was measured using both types of densitometers. Dose conversion was achieved with the established dose response curves for the respective densitometers. The dose values, along the seed's transverse axis obtained using both densitometers, were compared with each other, and also compared with published thermoluminescent dosimeter (TLD) data and Monte Carlo results. General agreement was found. It was concluded that the high-sensitivity GafChromic film measurement is a feasible method for 125I seed dosimetry in solid water phantom.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

建立了高灵敏度GafChromic薄膜对来自125I种子的光子在高达200 Gy剂量下的剂量响应。使用两种类型的密度计测量光密度:(a)具有宽带光谱的Macbeth点密度计,以及(b)具有波长632.8 nm红光的LKB氦氖激光扫描微密度计。发现对于Macbeth和LKB密度计,净光密度分别是剂量的幂函数,指数分别为0.858和0.997。使用LKB密度计时薄膜的灵敏度约为使用Macbeth密度计时的两倍。在固体水模体中使用高灵敏度GafChromic薄膜对125I型号6702种子进行剂量测量。每张薄膜平行于种子的长轴放置,并以种子的横轴为中心。薄膜在从接触种子到距离种子中心3 cm的不同距离处进行曝光。传递到薄膜中心的辐射剂量根据距离不同,从7到50 Gy不等。使用两种类型的密度计测量薄膜中心的光密度。通过为各自的密度计建立的剂量响应曲线实现剂量转换。将使用两种密度计在种子横轴上获得的剂量值相互比较,并与已发表的热释光剂量计(TLD)数据和蒙特卡罗结果进行比较。发现总体一致。得出结论,高灵敏度GafChromic薄膜测量是在固体水模体中进行125I种子剂量测定的可行方法。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验