Suppr超能文献

[一种测量膀胱顺应性降低患者膀胱血流的新方法]

[A new method of measurement of the urinary bladder blood flow in patients with low compliant bladder].

作者信息

Ohnishi N, Kishima Y, Hashimoto K, Kiwamoto H, Esa A, Sugiyama T, Park Y C, Kurita T

机构信息

Department of Urology, Kinki University School of Medicine.

出版信息

Hinyokika Kiyo. 1994 Aug;40(8):663-7.

PMID:7942362
Abstract

Laser-doppler blood flowmetry, a new instrument for measurement of tissue blood flow, was used to evaluate the changes occurring in the bladder blood flow and the intravesical pressure during bladder distension in 4 patients with normal detrusor function, 4 patients with neurogenic bladder dysfunction and one patient with non-neurogenic contracted bladder. In patients with normal detrusor function and normal compliance, the bladder blood flow relatively decreased, but the intravesical pressure was not affected by the bladder distension. On the other hand, the bladder distension in patients with low compliant bladder caused a significant decrease of the bladder blood flow and marked increase of the intravesical pressure. These observations suggest that the reduction of the bladder compliance is related to the decrease of the bladder blood flow. Furthermore, the bladder over distension and the high intravesical pressure in patients with low compliant bladder are thought to induce deterioration of bladder compliance and upper urinary tract.

摘要

激光多普勒血流仪是一种用于测量组织血流的新型仪器,用其评估4例逼尿肌功能正常的患者、4例神经源性膀胱功能障碍患者及1例非神经源性膀胱挛缩患者在膀胱扩张期间膀胱血流及膀胱内压的变化。在逼尿肌功能正常且顺应性正常的患者中,膀胱血流相对减少,但膀胱扩张未影响膀胱内压。另一方面,膀胱顺应性低的患者膀胱扩张导致膀胱血流显著减少及膀胱内压明显升高。这些观察结果提示膀胱顺应性降低与膀胱血流减少有关。此外,膀胱顺应性低的患者膀胱过度扩张及高膀胱内压被认为会导致膀胱顺应性及上尿路恶化。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验