Smith C W, Messenger J C, Schaner S P, Renner J W
Department of Radiology, Memorial Medical Center, Long Beach, CA.
Radiology. 1994 Dec;193(3):739-42. doi: 10.1148/radiology.193.3.7972816.
To develop improved methods of extracting pacemaker electrodes from the femoral vein by using standard equipment and techniques.
Pacemaker electrodes were removed from 61 patients aged 21-91 years (mean, 68 years). In 25 patients (41%), traction was applied to locking stylets to remove electrodes at the subclavian vein entry site. In 30 patients, the electrode tip was freed with traction at the subclavian vein entry site. The electrode was then extracted through a sheath placed in the femoral vein. In six patients (10%), the electrode tip was freed via the femoral vein when traction was applied to grasping devices. The electrode was then removed through a femoral venous sheath.
Ninety-nine (95%) of 104 pacemaker electrodes were extracted completely. Two electrodes were trapped in fibrous tissue in the subclavian vein. One right atrial tear occurred.
Pacemaker electrodes can be removed effectively by using percutaneous techniques.
利用标准设备和技术开发改进的从股静脉取出起搏器电极的方法。
从61例年龄在21 - 91岁(平均68岁)的患者身上取出起搏器电极。25例患者(41%)通过对锁定探针施加牵引力在锁骨下静脉入口处取出电极。30例患者中,在锁骨下静脉入口处通过牵引使电极尖端松解。然后通过置于股静脉的鞘管取出电极。6例患者(10%)在对抓取装置施加牵引力时,经股静脉使电极尖端松解。然后通过股静脉鞘管取出电极。
104根起搏器电极中的99根(95%)被完全取出。2根电极被困在锁骨下静脉的纤维组织中。发生1例右心房撕裂。
使用经皮技术可有效取出起搏器电极。