• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Pulse repetition rate increases the minimum threshold and latency of auditory neurons.

作者信息

Chen Q C, Jen P H

机构信息

Division of Biological Sciences, University of Missouri-Columbia 65211.

出版信息

Brain Res. 1994 Aug 15;654(1):155-8. doi: 10.1016/0006-8993(94)91582-2.

DOI:10.1016/0006-8993(94)91582-2
PMID:7982089
Abstract

The effect of pulse repetition rate on auditory sensitivity of the big brown bat, Eptesicus fuscus, was studied by determining the minimum threshold, response latency and recovery cycle of inferior collicular neurons at different repetition rates under free field stimulation conditions. In general, collicular neurons shortened the response latency and increased the number of impulses monotonically or non-monotonically with stimulus intensity. They recovered at least 50% when the interpulse interval was 10-57 ms. In addition, they increased the minimum threshold, lengthened the response latency, and reduced the number of impulses discharged to each pulse with increasing repetition rate. The increase in minimum threshold with repetition rate is partly because the neuron can not recover from previous stimulation when the interpulse interval is shortened. This increase reduces a neuron's response sensitivity and thus diminishes its number of impulses to each presented pulse. This increase also reduces the effectiveness of a given stimulus intensity which contributes to the lengthening of the neuron's response latency. Data obtained from single neuron recordings are used to highlight these observations. Implications of present findings regarding the bat's echolocation are also discussed.

摘要

相似文献

1
Pulse repetition rate increases the minimum threshold and latency of auditory neurons.
Brain Res. 1994 Aug 15;654(1):155-8. doi: 10.1016/0006-8993(94)91582-2.
2
Neurons in the inferior colliculus, auditory cortex and pontine nuclei of the FM bat, Eptesicus fucus respond to pulse repetition rate differently.
Brain Res. 1993 Jun 4;613(1):152-5. doi: 10.1016/0006-8993(93)90466-z.
3
Pulse repetition rate and duration affect the responses of bat auditory cortical neurons.脉冲重复率和持续时间会影响蝙蝠听觉皮层神经元的反应。
Chin J Physiol. 1992;35(4):259-78.
4
The effect of pulse repetition rate, pulse intensity, and bicuculline on the minimum threshold and latency of bat inferior collicular neurons.
J Comp Physiol A. 1998 Apr;182(4):455-65. doi: 10.1007/s003590050193.
5
Directional sensitivity of bat inferior collicular neurons determined under normal and monaurally plugged ear conditions.在正常和单耳堵塞条件下测定蝙蝠下丘神经元的方向敏感性。
Chin J Physiol. 1991;34(4):371-86.
6
Responses of inferior collicular neurons of the FM bat, Eptesicus fuscus, to pulse trains with varied pulse amplitudes.
Hear Res. 1994 Sep;79(1-2):105-14. doi: 10.1016/0378-5955(94)90132-5.
7
Responses of pontine neurons of the big brown bat, Eptesicus fuscus, to temporally patterned sound pulses.
Hear Res. 1995 May;85(1-2):155-68. doi: 10.1016/0378-5955(95)00042-3.
8
Duration selectivity of bat inferior collicular neurons improves with increasing pulse repetition rate.
Chin J Physiol. 2006 Feb 28;49(1):46-55.
9
The role of GABAergic inhibition in shaping directional selectivity of bat inferior collicular neurons determined with temporally patterned pulse trains.
J Comp Physiol A Neuroethol Sens Neural Behav Physiol. 2002 Nov;188(10):815-26. doi: 10.1007/s00359-002-0367-x. Epub 2002 Nov 15.
10
GABAergic disinhibition affects responses of bat inferior collicular neurons to temporally patterned sound pulses.γ-氨基丁酸能去抑制作用影响蝙蝠下丘神经元对具有时间模式的声脉冲的反应。
J Neurophysiol. 1998 May;79(5):2303-15. doi: 10.1152/jn.1998.79.5.2303.

引用本文的文献

1
Neural Processing of Naturalistic Echolocation Signals in Bats.蝙蝠对自然声纳信号的神经处理。
Front Neural Circuits. 2022 May 18;16:899370. doi: 10.3389/fncir.2022.899370. eCollection 2022.
2
Sodium salicylate alters temporal integration measured through increasing stimulus presentation rates.水杨酸钠通过增加刺激呈现率改变时间整合的测量。
Int J Audiol. 2019 Mar;58(3):141-150. doi: 10.1080/14992027.2018.1544424.
3
Processing of Natural Echolocation Sequences in the Inferior Colliculus of Seba's Fruit Eating Bat, .Seba 的果蝠下丘脑中自然回声定位序列的处理。
eNeuro. 2017 Dec 13;4(6). doi: 10.1523/ENEURO.0314-17.2017. eCollection 2017 Nov-Dec.
4
Dynamic temporal signal processing in the inferior colliculus of echolocating bats.下丘脑中回声定位蝙蝠的动态时间信号处理。
Front Neural Circuits. 2012 May 8;6:27. doi: 10.3389/fncir.2012.00027. eCollection 2012.
5
Activation of serotonin 3 receptors changes in vivo auditory responses in the mouse inferior colliculus.血清素3受体的激活会改变小鼠下丘的体内听觉反应。
Hear Res. 2009 May;251(1-2):29-38. doi: 10.1016/j.heares.2009.02.006. Epub 2009 Feb 21.
6
Temporally patterned pulse trains affect directional sensitivity of inferior collicular neurons of the big brown bat, Eptesicus fuscus.具有时间模式的脉冲序列会影响大棕蝠(棕蝠)下丘神经元的方向敏感性。
J Comp Physiol A. 1996 Sep;179(3):385-93. doi: 10.1007/BF00194992.