The efficacy and safety in using a new low-profile perfusion balloon catheter (PBC) as the initial balloon in percutaneous coronary angioplasty (PTCA) was assessed retrospectively in 61 patients: 43 males, mean age 62 +/- 12 years. Thirty-three patients (54%) had unstable angina. PTCA was performed using an improved PBC in the following vessels: LAD 40%; CX 21%; RCA 24%. Lesion morphology was: Type A 21%; Type B1 18%; Type B2 40%; Type C 21%. Mean artery size was 3.01 +/- 0.53 mm. Mean PBC size was 3.14 +/- 0.45 mm. The mean number of inflations used was 2.85 +/- 2.0. The mean longest inflation was 415 +/- 213 sec and the total inflation time was 663 +/- 342 sec to a mean maximum pressure atmosphere of 7.85 +/- 2.0 bars. The number of balloons used per procedure was 1.2 +/- 0.44. In 50 patients (82%) only one balloon was used during the PTCA. PTCA was successful (< 50% diameter stenosis without major complications) in 60 patients (98.4%). Mean diameter stenosis at baseline was 82 +/- 9.5% and post-angioplasty 13 +/- 10.6%. A mild intimal tear occurred in 6 patients (9.8%). A stent was implanted in 3 patients (4.9%) due to severe dissection. In hospital reocclusion occurred in one patient (1.6%). There were no deaths or emergency bypass surgery. A low profile PBC is safe and effective as an initial balloon in PTCA. It may reduce the number of balloons used and inflations per procedure.

摘要

回顾性评估了61例患者使用新型低轮廓灌注球囊导管(PBC)作为经皮冠状动脉腔内血管成形术(PTCA)初始球囊的有效性和安全性:43例男性,平均年龄62±12岁。33例患者(54%)患有不稳定型心绞痛。在以下血管中使用改良的PBC进行PTCA:左前降支(LAD)40%;回旋支(CX)21%;右冠状动脉(RCA)24%。病变形态为:A型21%;B1型18%;B2型40%;C型21%。平均动脉直径为3.01±0.53mm。平均PBC尺寸为3.14±0.45mm。平均充盈次数为2.85±2.0次。平均最长充盈时间为415±213秒,总充盈时间为663±342秒,平均最大压力为7.85±2.0巴。每次手术使用的球囊数量为1.2±0.44个。50例患者(82%)在PTCA期间仅使用了一个球囊。60例患者(98.4%)PTCA成功(直径狭窄<50%且无重大并发症)。基线时平均直径狭窄为82±9.5%,血管成形术后为13±10.6%。6例患者(9.8%)出现轻度内膜撕裂。3例患者(4.9%)因严重夹层植入了支架。1例患者(1.6%)在住院期间发生再闭塞。无死亡病例或急诊搭桥手术。低轮廓PBC作为PTCA的初始球囊是安全有效的。它可能会减少每次手术使用的球囊数量和充盈次数。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验