Lincoff's development of silicone sponge and substitution cryosurgery for diathermy in the mid-1960s, was the beginning of the minimized surgery for retinal detachment, limited to the surgery of the breaks. The aim of this paper is to present our experiences with these kinds of operations, with special attention to the complications causing the necessity of removing the sponge. Our studies concerned the patients who underwent retinal detachment surgery, in the Ophthalmological Clinic in Cracow in the years 1983-1992, using scleral buckling procedures with silicone sponge. In 152 cases circumferential and in 36 radial local scleral buckling procedures were performed; in 30 cases local buckling was added to encirclement with silicone band. The complications, attributed to the sponge, were observed in 9.7% of cases. Anterior segment inflammatory reactions, often sterile were found in 15 eyes, in 7 of them it was necessary to remove the sponge. In 13 eyes the sponge was removed on account of its extrusion. In none of the cases removal of the sponge influenced the retinal attachment. Our studies confirmed, that silicone sponge is a very good material for scleral buckling procedures.
20世纪60年代中期林科夫开发的硅海绵并将冷冻手术替代透热疗法,开启了视网膜脱离微创手术的先河,该手术仅限于治疗裂孔。本文旨在介绍我们在这类手术中的经验,特别关注导致必须取出海绵的并发症。我们的研究涉及1983年至1992年期间在克拉科夫眼科诊所接受视网膜脱离手术的患者,采用硅海绵巩膜扣带术。其中152例进行了环形巩膜扣带术,36例进行了放射状局部巩膜扣带术;30例在使用硅橡胶带进行环扎的基础上增加了局部扣带术。9.7%的病例出现了归因于海绵的并发症。15只眼中发现了前段炎症反应,通常为无菌性,其中7只眼有必要取出海绵。13只眼因海绵挤出而取出。在所有病例中,取出海绵均未影响视网膜复位。我们的研究证实,硅海绵是巩膜扣带术的一种非常好的材料。