Lindblad H G, Berg U B
Department of Paediatrics, Huddinge University Hospital, Karolinska Institute, Sweden.
Acta Paediatr. 1994 Apr;83(4):418-22. doi: 10.1111/j.1651-2227.1994.tb18133.x.
We evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin (r = 0.834). The clearance of iohexol correlated well (r = 0.672) with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patients with relatively normal filtration rates. We conclude that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice.
我们在150名儿童中评估了碘海醇作为滤过标志物的情况。将碘海醇的清除率与菊粉清除率或公式计算的清除率进行了比较。碘海醇的单次样本清除率与菊粉清除率显示出良好的相关性(r = 0.834)。碘海醇清除率与公式计算的清除率相关性良好(r = 0.672)。至少在滤过率相对正常的患者中,测定碘海醇清除率的最佳采血时间似乎在注射后120至180分钟之间。我们得出结论,在临床实践中,碘海醇清除率是测定肾小球滤过率的一种准确方法。