Abstract

Glomerular filtration rate (GFR) is the standard measure of renal function and is critical for the management of renal diseases. Rigorous assessment of GFR requires the measurement of renal clearance of a filtration marker, such as inulin. This method, however, is not suitable for routine clinical practice. Labelled compounds as alternative filtration markers provide accurate and precise GFR measurement, but their use may be limited for safety reasons. Thus investigators have proposed clearance procedures using minute doses of non-radioactive contrast agents, including iothalamate and iohexol. Their renal clearance provides similar accuracy as inulin clearance in GFR estimation, but the need of urine collection again poses certain limitations to the procedure. Thus, plasma clearance of suitable exogenous markers, such X-ray contrast media, has been suggested for measuring renal function, in which the elimination rate of the tracer after a single intravenous injection is evaluated. Plasma clearance of these markers estimated by multiple blood samples provides precise information, but repeated sampling makes this method cumbersome. Abbreviated kinetic profiles have been proposed to predict GFR from the plasma disappearance curve. The simplified method that uses a one-compartment model corrected by the Bröchner-Mortensen formula gives an excellent correlation with inulin clearance and is currently employed for measuring GFR in multi-centre clinical trials.

摘要

肾小球滤过率(GFR)是评估肾功能的标准指标,对肾脏疾病的管理至关重要。严格评估GFR需要测量滤过标志物的肾脏清除率,如菊粉。然而,这种方法不适用于常规临床实践。作为替代滤过标志物的标记化合物可提供准确且精确的GFR测量值,但出于安全考虑,其应用可能受到限制。因此,研究人员提出了使用微量非放射性造影剂(包括碘他拉酸盐和碘海醇)的清除程序。它们的肾脏清除率在GFR估算中提供了与菊粉清除率相似的准确性,但尿液收集的需求再次给该程序带来了一定限制。因此,有人建议使用合适的外源性标志物(如X射线造影剂)的血浆清除率来测量肾功能,其中评估单次静脉注射后示踪剂的消除率。通过多次采集血样估算这些标志物的血浆清除率可提供精确信息,但重复采样使该方法变得繁琐。有人提出了简化的动力学曲线,以便根据血浆消失曲线预测GFR。使用经布罗克纳 - 莫滕森公式校正的单室模型的简化方法与菊粉清除率具有极好的相关性,目前已用于多中心临床试验中测量GFR。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验