Suppr超能文献

高效液相色谱法测定肉类和肝脏中的硫胺素(维生素B1)和核黄素(维生素B2)

Determination of thiamine (vitamin B1) and riboflavin (vitamin B2) in meat and liver by high-performance liquid chromatography.

作者信息

Barna E, Dworschák E

机构信息

Department of Food Chemistry, National Institute of Food Hygiene and Nutrition, Budapest, Hungary.

出版信息

J Chromatogr A. 1994 May 13;668(2):359-63. doi: 10.1016/0021-9673(94)80126-6.

Abstract

HPLC methods described so far for the determination of thiamine and riboflavin in meat samples have used mostly fluorescence detection. The aim of this work was to elaborate a suitable method with UV detection for this purpose and to compare the thiamine and riboflavin contents obtained for meat and liver samples from various pig groups. Homogenized spare rib, chop, ham and liver samples were treated with acid and heated (at 121 degrees C, 30 min), followed by enzymatic digestion to release the vitamins. After a clean-up procedure the simultaneous determination of thiamine and riboflavin was performed with a Nucleosil ODS (3 microns) packed column at 45 degrees C. The mobile phase was phosphate buffer (pH 3.0)-acetonitrile (84:16, v/v) containing 5 mM sodium heptanesulphonate. The relative standard deviation was 5% for thiamine and 12% for riboflavin in meat and 8% for thiamine and 5% for riboflavin in liver for four parallel determinations.

摘要

到目前为止,所描述的用于测定肉类样品中硫胺素和核黄素的高效液相色谱法大多采用荧光检测。这项工作的目的是为此精心制定一种适合的紫外检测方法,并比较不同猪群的肉类和肝脏样品中硫胺素和核黄素的含量。将匀浆后的排骨、排骨块、火腿和肝脏样品用酸处理并加热(121℃,30分钟),然后进行酶消化以释放维生素。经过净化程序后,使用Nucleosil ODS(3微米)填充柱在45℃下同时测定硫胺素和核黄素。流动相为含有5 mM庚烷磺酸钠的磷酸盐缓冲液(pH 3.0)-乙腈(84:16,v/v)。四次平行测定时,肉类中硫胺素的相对标准偏差为5%,核黄素为12%;肝脏中硫胺素为8%,核黄素为5%。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验