Tigges S, Stiles R G, Roberson J R
Department of Radiology, Emory Clinic, Emory University School of Medicine, Atlanta, GA 30322.
AJR Am J Roentgenol. 1994 Aug;163(2):377-80. doi: 10.2214/ajr.163.2.8037035.
The purpose of this study was to evaluate the spectrum of plain radiographic findings in patients with septic hip prostheses.
Radiographs of 20 confirmed infected hip prostheses were examined for the presence or absence of lucency, type of lucency (focal or nonfocal), rapidity of radiographic change, periostitis, subsidence, and cement fracture.
Findings were normal in 10 prostheses, but nonfocal lucencies mimicking mechanical loosening were seen in four cases. Two cases showed focal bone loss, indistinguishable from aggressive granulomatosis. A variety of findings, including subsidence and periostitis, were seen in the remaining four prostheses.
Plain radiographs of septic hip prostheses often show normal findings but can show focal bone loss that mimics aggressive granulomatosis.
本研究的目的是评估感染性髋关节假体患者的X线平片表现谱。
对20例确诊为感染性髋关节假体的X线片进行检查,观察是否存在透亮区、透亮区类型(局灶性或非局灶性)、X线变化的速度、骨膜炎、下沉和骨水泥骨折情况。
10个假体表现正常,但4例可见类似机械性松动的非局灶性透亮区。2例显示局灶性骨质丢失,与侵袭性肉芽肿难以区分。其余4个假体可见多种表现,包括下沉和骨膜炎。
感染性髋关节假体的X线平片常显示正常表现,但也可显示类似侵袭性肉芽肿的局灶性骨质丢失。