OBJECTIVE

The purpose of this study was to determine the efficacy of sonography in the detection of infection in loosened hip prostheses.

MATERIALS AND METHODS

The normal capsular morphology in 15 asymptomatic patients with total hip replacements was studied sonographically. Sonograms were then obtained in 33 patients who had pain in the hip after arthroplasty and radiologic findings of loosening of the prosthesis. These patients subsequently underwent aspiration and arthrography of the hip. Six of the 33 symptomatic patients proved to have prosthetic joint infection.

RESULTS

On sonograms, the normal pseudocapsule is adherent to the proximal part of the anterior femoral cortex, and the capsule-to-bone distance is less than 3.2 mm (average, 2.6 mm). No hips with a capsule-to-bone distance less than 3.2 mm were infected. Sonograms in the six patients with infection showed marked intraarticular effusion with a mean capsule-to-bone distance of 10.2 mm. Five of these six had extracapsular fluid collections. Two patients with hip dislocations and four with aseptic loosening of the prosthesis had capsular distension on sonograms and cultures of aspirated material that showed no growth.

CONCLUSION

Sonography can be used to diagnose infection around loosened hip prostheses. All patients who had an intraarticular effusion with extraarticular extension seen on sonograms had infection.

摘要

目的

本研究的目的是确定超声检查在检测松动髋关节假体感染方面的有效性。

材料与方法

对15例无症状全髋关节置换患者的正常关节囊形态进行超声检查。然后对33例关节置换术后髋关节疼痛且假体有松动影像学表现的患者进行超声检查。这些患者随后接受了髋关节穿刺和关节造影。33例有症状的患者中有6例被证实患有假体关节感染。

结果

在超声图像上,正常的假关节囊附着于股骨前皮质近端,关节囊与骨的距离小于3.2mm(平均2.6mm)。关节囊与骨的距离小于3.2mm的髋关节均未感染。6例感染患者的超声图像显示关节内有明显积液,关节囊与骨的平均距离为10.2mm。这6例中有5例有囊外积液。2例髋关节脱位和4例假体无菌性松动患者的超声图像显示关节囊扩张,穿刺物培养无生长。

结论

超声检查可用于诊断松动髋关节假体周围的感染。超声图像上显示有关节内积液并伴有关节外扩展的所有患者均有感染。