Cordero-Ampuero J, Garcia-Cimbrelo E, Munuera L
Department of Orthopedics, La Paz Hospital, Universidad Autónoma de Madrid, Spain.
Acta Orthop Scand. 1994 Jun;65(3):263-6. doi: 10.3109/17453679408995451.
We studied fixation changes over time in 113 porous-coated Howmedica (PCA) cementless acetabular cups inserted in 90 patients 1984-1988. The mean follow-up was 5 years. Radiographic fixation was classified as stable, fibrous-stable, or unstable. 9 cups, 3 in neutral position and 6 vertical, were revised. At follow-up, 40/75 neutral cups were stable versus 7/27 vertical cups. Most stable cups and two thirds of the unstable cups were clinically good. After the first 2 years, 28/75 neutral cups and 10/27 vertical cups changed their fixation; 12 had improved fixation and 26 had a worse one.
我们研究了1984年至1988年期间为90例患者植入的113个多孔涂层豪美蒂卡(PCA)非骨水泥髋臼杯随时间的固定变化情况。平均随访时间为5年。放射学固定分为稳定、纤维性稳定或不稳定。9个杯进行了翻修,其中3个处于中立位,6个垂直位。随访时,75个中立位杯中有40个稳定,而27个垂直位杯中有7个稳定。大多数稳定杯和三分之二的不稳定杯临床效果良好。在最初2年后,75个中立位杯中有28个、27个垂直位杯中有10个改变了固定情况;12个固定情况改善,26个变差。