Wilmore K M, McBride P J, Wilmore J H
Human Performance Laboratory, University of Texas at Austin 78712.
Int J Obes Relat Metab Disord. 1994 Jun;18(6):375-81.
This study was conducted to determine the reliability and validity of bioelectric impedance (BIA) and near-infrared interactance (NIR) for body composition assessment in a population that considered themselves to be overweight, using hydrostatic weighing (HW) as the criterion method. Skinfold measurements were also taken for comparison, and the Jackson and Pollock (J-P) and Durnin and Womersley (D-W) equations were used to determine relative body fat. One hundred men and women, ages 18-61, with 15.5-43.3% body fat participated in the study. Reliability correlations for relative body fat (n = 19) were high for the skinfold equations (r = 0.99) and BIA (r = 0.95) and lower for NIR (r = 0.88). Analysis of variance showed that BIA, NIR, and J-P all significantly underestimated relative body fat in this population, while D-W significantly overestimated relative body fat. BIA, relative to HW, had correlations of r = 0.80-0.86 and SEEs of 3.4-3.6% body fat, while correlations for NIR were lower (r = 0.66-0.77) and SEEs were higher (3.8-4.3%) than for BIA. Correlations between D-W and HW ranged from r = 0.72 to 0.84 (SEE = 3.4-4.1%), while similar results were found for the J-P equations (r = 0.72 to 0.86, SEE = 3.0-4.1). BIA predicted 72% of the subjects within 4% of HW values while NIR, D-W, and J-P predicted only 61, 59 and 58%, respectively, within this same range.(ABSTRACT TRUNCATED AT 250 WORDS)
本研究旨在以水下称重法(HW)作为标准方法,确定生物电阻抗分析法(BIA)和近红外交互作用法(NIR)在自认为超重人群中进行身体成分评估的可靠性和有效性。还进行了皮褶测量以作比较,并使用杰克逊和波洛克(J-P)方程以及达宁和沃姆斯利(D-W)方程来确定相对体脂。100名年龄在18至61岁、体脂率在15.5%至43.3%之间的男性和女性参与了该研究。皮褶方程(r = 0.99)和BIA(r = 0.95)对相对体脂(n = 19)的可靠性相关性较高,而NIR的相关性较低(r = 0.88)。方差分析表明,在该人群中,BIA、NIR和J-P均显著低估了相对体脂,而D-W则显著高估了相对体脂。相对于HW,BIA的相关性为r = 0.80 - 0.86,估计标准误(SEE)为体脂的3.4% - 3.6%,而NIR的相关性较低(r = 0.66 - 0.77),SEE较高(3.8% - 4.3%)。D-W与HW之间的相关性范围为r = 0.72至0.84(SEE = 3.4% - 4.1%),J-P方程也得到了类似结果(r = 0.72至0.86,SEE = 3.0% - 4.1%)。BIA在HW值的4%范围内预测了72%的受试者,而NIR、D-W和J-P在同一范围内分别仅预测了61%、59%和58%的受试者。(摘要截断于250字)