A comparison of the accuracy of the Siemens injection vaporizer and the Enfluratec 3 vaporizer.

作者信息

Cozanitis D A, Rosenberg P H, Merrett J D

机构信息

Department of Anaesthesia, University of Helsinki.

出版信息

Anaesthesiol Reanim. 1994;19(3):75-7.

PMID:8086093
Abstract

The accuracy of two Siemens injection vaporizers was examined under operating theatre conditions. For comparison, two Enfluratec 3 vaporizers were tested. The concentrations of enflurane produced by the vaporizers were measured both by an anaesthetic agent monitor and by chromatography. Five experimental modes were used with enflurane delivered either in air/oxygen or in nitrous oxide/oxygen mixtures and the experiments were repeated five times. In every case, the mean concentration values produced by the anaesthetic agent monitor were higher than those obtained by chromatography. The difference may have been due to leakage of the gas sample from the "gas-tight" syringes and/or improper calibration of either analyzer. The Siemens devices were less reliable than the Enfluratecs when enflurane was given in nitrous oxide/oxygen. The former vaporizers seem to be less robust than the Enfluratecs and should be used according to the manufacturer's recommendations. The pressures in the central system were higher than those called for. In addition, improper coupling of the Siemens apparatus to the ventilator may well have influenced the results.

摘要

相似文献

1
A comparison of the accuracy of the Siemens injection vaporizer and the Enfluratec 3 vaporizer.
Anaesthesiol Reanim. 1994;19(3):75-7.
2
The Diamedica Draw-Over Vaporizer: a comparison of a new vaporizer with the Oxford Miniature Vaporizer.迪美迪卡抽拉式蒸发器:新型蒸发器与牛津微型蒸发器的比较。
Anaesthesia. 2009 Jan;64(1):84-92. doi: 10.1111/j.1365-2044.2008.05739.x.
3
Nitrous oxide increases enflurane concentrations delivered by Ethrane vaporizers.
Anesth Analg. 1979 Jan-Feb;58(1):30-2. doi: 10.1213/00000539-197901000-00010.
4
Performance of erroneously filled sevoflurane, enflurane and other agent-specific vaporizers.
J Clin Monit. 1996 Mar;12(2):119-25. doi: 10.1007/BF02078132.
5
Accuracy of 94 anaesthetic agent vaporizers in clinical use.
Br J Anaesth. 1993 Sep;71(3):453-7. doi: 10.1093/bja/71.3.453.
6
Assessment of vaporizer performance in low-flow and closed-circuit anesthesia.低流量和闭环麻醉中蒸发器性能的评估。
Anesth Analg. 1980 May;59(5):359-66.
7
Enflurane vaporizer accuracy with nitrous oxide mixtures.
Anesth Analg. 1979 Sep-Oct;58(5):440-1. doi: 10.1213/00000539-197909000-00022.
8
[Dysfunction of vaporizers and nitrous oxide: solubility or viscosity?].
Ann Fr Anesth Reanim. 1994;13(1):27-32. doi: 10.1016/s0750-7658(94)80184-3.
9
[Occupational exposure to enflurane and laughing gas in operating rooms].[手术室中职业性接触安氟醚和笑气]
Zentralbl Hyg Umweltmed. 1996 Feb;198(3):265-74.
10
The output of four modern vaporizers in the presence of helium.
Can J Anaesth. 1992 Oct;39(8):888-91. doi: 10.1007/BF03008301.