Suppr超能文献

Electrodiagnostics of chiasmal compressive lesions.

作者信息

Brecelj J

机构信息

University Institute of Clinical Neurophysiology, Medical Centre, Ljubljana, Slovenia.

出版信息

Int J Psychophysiol. 1994 May;16(2-3):263-72. doi: 10.1016/0167-8760(89)90053-6.

Abstract

Recording of visual evoked potentials (VEPs) is not yet a routine test in patients with suspected chiasmal compressive lesions, but has proved useful to a clinician in assessing and following-up visual pathway dysfunctions. Abnormalities of VEPs can be found even in patients without clinical evidence of the visual impairment: VEP delays and alterations of the waveform, asymmetric distribution in one eye or in both eyes (crossed asymmetry) can indicate chiasmal compressive lesion. Simultaneous recording of pattern electroretinograms (PERGs) can additionally provide useful information about the patient's cooperation as well as about eventual retrograde degeneration of the ganglion cells. Electrophysiologic tests can be regarded as an integral part of diagnostic procedures--ocular diagnostic tests and neuroimaging--in suspected compressive lesions of the optic chiasm.