• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Validity and feasibility of nasopharyngeal end-tidal carbon dioxide tension monitorings: a novel approach in spontaneous breathing patients.

作者信息

Hou W Y, Sun W Z, Susceto L, Huang H H, Cherng Y G, Shi J J, Lin C S, Lin S Y

机构信息

Department of Anesthesiology, National Taiwan University Hospital, Taipei, R.O.C.

出版信息

J Formos Med Assoc. 1993 Jun;92(6):553-7.

PMID:8106044
Abstract

Conventional end-tidal CO2 (Pe'CO2) monitoring is difficult and impractical in nonintubated patients who are either sedated or anesthetized while spontaneous respiration is maintained. An alternative technique using nasopharyngeal end-tidal carbon dioxide tension (PNe,CO2) has been developed. The present study evaluates the feasibility and validity of PNe,CO2 as a reliable respiratory monitoring method. Sixty patients in ASA class status I or II and scheduled for elective surgery were divided into two groups. In group 1 (n = 30), conventional Pe'CO2 was used in intubated patients under general anesthesia. In group 2 (n = 30), PNe,CO2 monitoring was used in patients under regional anesthesia with spontaneous respiration maintained. A 12 FG suction catheter, connected to the sampling tube of a CO2 analyzer, was inserted via the nasal airway to within 1 cm of the nasopharyngeal orifice. Arterial blood gas (PaCO2) was sampled 25 minutes after the operation began, Pe'CO2 (group 1) and PNe,CO2 (group 2) were recorded simultaneously. In both groups, PaCO2 was highly correlated with Pe'CO2 (r = 0.6938) and PNe,CO2 (r = 0.8613). The difference between the two values, (a-e')PCO2 = 0.35 +/- 0.33kPa and (a-Ne')PCO2 = -0.1 +/- 0.51kPa, indicates that PNe,CO2 is more closely correlated to PaCO2 than conventional Pe'CO2. The reduced (a-Ne')PCO2 in group 2 may be explained by CO2 rebreathing and a reduced respiratory deadspace during anesthesia and spontaneous breathing. Interestingly, 60% of the (a-Ne')PCO2 measurements were negative values, suggesting that PNe,CO2 and a spatial V/Q mismatch is caused by sedation; higher CO2 production and CO2 rebreathing may explain the results.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Validity and feasibility of nasopharyngeal end-tidal carbon dioxide tension monitorings: a novel approach in spontaneous breathing patients.
J Formos Med Assoc. 1993 Jun;92(6):553-7.
2
Relationship between end-tidal and arterial carbon dioxide partial pressure using a cuffed oropharyngeal airway and a tracheal tube.
Br J Anaesth. 1998 Feb;80(2):253-4. doi: 10.1093/bja/80.2.253.
3
Correlation of arterial and end-tidal carbon dioxide in spontaneously breathing patients during ambulatory gynecologic laparoscopy.门诊妇科腹腔镜检查期间自主呼吸患者动脉血与呼气末二氧化碳的相关性
J Formos Med Assoc. 1999 Dec;98(12):814-9.
4
Arterial-to-end-tidal carbon dioxide tension difference in children with congenital heart disease.先天性心脏病患儿的动脉血与呼气末二氧化碳分压差值
J Cardiothorac Vasc Anesth. 2006 Apr;20(2):196-201. doi: 10.1053/j.jvca.2005.11.008.
5
Variation in the arterial to end-tidal PCO2 difference during one-lung thoracic anaesthesia.
Br J Anaesth. 1994 Jan;72(1):21-4. doi: 10.1093/bja/72.1.21.
6
End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.自主呼吸的非插管患者的呼气末二氧化碳监测。传统旁流式与微流式二氧化碳监测仪的临床比较。
Minerva Anestesiol. 2001 Apr;67(4):161-4.
7
Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration.麻醉和人工通气期间的死腔及二氧化碳单次呼吸试验。潮气量和呼吸频率的影响。
Br J Anaesth. 1984 Feb;56(2):109-19. doi: 10.1093/bja/56.2.109.
8
Single breath end-tidal CO2 estimates of arterial PCO2 in infants and children.
Can J Anaesth. 1989 Mar;36(2):110-2. doi: 10.1007/BF03011429.
9
Blood-gas equilibration of CO2 and O2 in lungs of awake dogs during prolonged rebreathing.清醒犬在长时间重复呼吸过程中肺内二氧化碳和氧气的血气平衡
J Appl Physiol Respir Environ Exerc Physiol. 1984 Nov;57(5):1354-9. doi: 10.1152/jappl.1984.57.5.1354.
10
Comparison between the cuffed oropharyngeal airway and the laryngeal mask with respect to breathing pattern and capnography.带套囊口咽气道与喉罩在呼吸模式和二氧化碳描记图方面的比较。
Acta Anaesthesiol Belg. 2001;52(2):191-9.