Suppr超能文献

羊水磷脂酰甘油的酶法测定。

Enzymatic measurement of phosphatidylglycerol in amniotic fluid.

作者信息

Jones G W, Ashwood E R

机构信息

Department of Pathology, University of Utah, School of Medicine, Salt Lake City 84132.

出版信息

Clin Chem. 1994 Apr;40(4):518-25.

PMID:8149604
Abstract

We describe an enzymatic method for measuring phosphatidylglycerol (PG) at concentrations as low as 0.2 mumol/L in amniotic fluid. Amniotic fluid (1.5 mL) is centrifuged at 10,000g for 20 min to obtain a lamellar body pellet, which is reconstituted with 0.5 mL of buffer. The PG is measured by a two-step enzymatic scheme. Recovery studies demonstrated that the pellet contains > 97% of the PG present in amniotic fluid. Between-run CVs were 28%, 5.7%, and 2.6% for amniotic fluid controls with means of 0.32, 3.9, and 10.7 mumol/L, respectively (n = 20). The enzymatic procedure was not significantly affected by blood, meconium, bilirubin, or other phospholipids. Lecithin/sphingomyelin ratio (n = 101) and fluorescence polarization (n = 127) compared with log(PG) showed correlation coefficients of 0.832 and -0.866, respectively. This test's ability to detect low concentrations of PG in amniotic fluid may make it a better predictor of fetal lung immaturity than previous methods.

摘要

我们描述了一种酶法,用于测量羊水中低至0.2 μmol/L浓度的磷脂酰甘油(PG)。将1.5 mL羊水在10,000g下离心20分钟以获得板层体沉淀,该沉淀用0.5 mL缓冲液复溶。PG通过两步酶法进行测量。回收率研究表明,沉淀中含有羊水中97%以上的PG。羊水对照品的批间CV分别为28%、5.7%和2.6%,平均值分别为0.32、3.9和10.7 μmol/L(n = 20)。该酶法不受血液、胎粪、胆红素或其他磷脂的显著影响。与log(PG)相比,卵磷脂/鞘磷脂比值(n = 101)和荧光偏振(n = 127)的相关系数分别为0.832和-0.866。该检测方法检测羊水中低浓度PG的能力可能使其比以前的方法更能预测胎儿肺不成熟。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验