Limulus peptide C, a 28-amino-acid fragment of coagulogen formed by the reaction of endotoxin with Limulus amebocyte lysate, was synthesized, and a monoclonal antibody against it was raised. A new microassay for endotoxin was developed, using this antibody in an enzyme-linked immunosorbent assay for generated peptide C-like immunoreactivity. A linear relationship between absorbance and endotoxin concentration was obtained. Control standard endotoxin in water could be detected to a level of 0.001 endotoxin unit per ml. The endotoxin levels in plasma samples from normal humans, rabbit, mice, and guinea pigs were generally found to be below the detection limit of 0.01 endotoxin unit per ml of plasma. The color and turbidity of specimens did not interfere with the assay. The consumption of Limulus amebocyte lysate in the assay was less than 5% of that in the gel-clot and chromogenic assays. With raw lysate, which was much more stable in solution than chloroform-treated lysate, the assay was still highly sensitive to endotoxin but was totally unresponsive to natural glucans. The monoclonal antibody cross-reacted with peptide C-like immunoreactivity generated in Tachypleus amebocyte lysate, which gave equal sensitivity in the endotoxin assay.
鲎肽C是内毒素与鲎变形细胞溶解物反应形成的凝血酶原的一个含28个氨基酸的片段,已被合成,并制备了针对它的单克隆抗体。利用该抗体进行酶联免疫吸附测定以检测生成的肽C样免疫反应性,开发了一种新的内毒素微量测定法。获得了吸光度与内毒素浓度之间的线性关系。水中的对照标准内毒素可检测到每毫升0.001内毒素单位的水平。一般发现正常人、兔、小鼠和豚鼠血浆样本中的内毒素水平低于每毫升血浆0.01内毒素单位的检测限。样本的颜色和浊度不干扰测定。该测定中鲎变形细胞溶解物的消耗量不到凝胶凝块法和显色法的5%。使用在溶液中比经氯仿处理的溶解物更稳定的粗溶解物,该测定对内毒素仍高度敏感,但对天然葡聚糖完全无反应。该单克隆抗体与在东方鲎变形细胞溶解物中产生的肽C样免疫反应性发生交叉反应,在该内毒素测定中具有相同的灵敏度。