Suppr超能文献

Fast-neutron dose rate vs energy for the d+Be reaction--a reanalysis.

作者信息

Smathers J B, Otte V A, Smith A R, Almond P R

出版信息

Med Phys. 1976 Jan-Feb;3(1):45-7. doi: 10.1118/1.594229.

Abstract

The differences in the published information concerning tissue kerma in air vs deuteron energy for the d+Be reaction are analyzed in light of some recent measurements. The reason for the discrepancy is determined to be a lack of electron suppression on the Be target in some earlier measurements, and the relation ln(tissue kerma)=ln(1.356 X 10(-4)+2.97lnE is found to fit the measured data over the deuteron energy range 11-50 MeV.

摘要

相似文献

1
Fast-neutron dose rate vs energy for the d+Be reaction--a reanalysis.
Med Phys. 1976 Jan-Feb;3(1):45-7. doi: 10.1118/1.594229.
6
High energy fast neutrons from the Harwell variable energy cyclotron. I. Physical characteristics.
AJR Am J Roentgenol. 1977 Oct;129(4):709-16. doi: 10.2214/ajr.129.4.709.
7
Dosimetry intercomparisons between fast-neutron radiotherapy facilities.
Med Phys. 1975 Jul-Aug;2(4):195-200. doi: 10.1118/1.594178.