Dill K, Lin M, Poteras C, Fraser C, Hafeman D G, Owicki J C, Olson J D
Molecular Devices, Menlo Park, California 94025.
Anal Biochem. 1994 Feb 15;217(1):128-38. doi: 10.1006/abio.1994.1093.
Affinities of various monoclonal and polyclonal antibodies for fluorescein-containing antigens, saxitoxin and ricin, were determined by using a light addressable potentiometric sensor-based system (Threshold). The dissociation constants, determined from Scatchard plots, ranged from 2 x 10(-7) to approximately 3 x 10(-12) M. Dissociation constants for fluorescein and saxitoxin were compared with values determined by independent means. This technique was found to be quick, simple, reproducible, and accurate.