Spectral sensitivity in the red-green spectral range typically reflects the joint influence of the middle-wavelength-sensitive cones (the M or green cones) and long-wavelength-sensitive cones (the L or red cones). The balance of M- and L-cone influence can be altered by presenting the test lights superimposed upon steady background fields of long or short wavelength. We find that presenting test stimuli just after an abrupt exchange between two colored backgrounds permits an easier and closer approach to cone isolation than presenting them either on a steady background or following an intense bleach. Background exchange drives the flicker detection or flicker photometric spectral sensitivities measured at 17 Hz to a limiting condition at lower intensities than do steady backgrounds. This condition is consistent with either M- or L-cone isolation. Steady backgrounds do not produce complete cone isolation: even on backgrounds that push spectral sensitivity closest to M or L, there are substantial phase differences between flickering lights of different color. In contrast, no phase differences remain following background exchange. The improvement in cone isolation produced by the exchange procedure is not confined to flicker measurements: the spectral range over which subjects are temporarily monochromatic is more extended following background exchange than on steady fields.
红-绿光谱范围内的光谱敏感度通常反映了中波敏感视锥细胞(M或绿视锥细胞)和长波敏感视锥细胞(L或红视锥细胞)的共同影响。通过将测试光叠加在长波长或短波长的稳定背景场上,可以改变M视锥细胞和L视锥细胞影响的平衡。我们发现,在两种彩色背景之间突然切换后立即呈现测试刺激,比在稳定背景上或在强烈漂白后呈现测试刺激,能更轻松、更接近地实现视锥细胞分离。与稳定背景相比,背景切换能使在17Hz频率下测量的闪烁检测或闪烁光度光谱敏感度在更低强度下达到极限条件。这种条件与M或L视锥细胞分离一致。稳定背景无法实现完全的视锥细胞分离:即使在使光谱敏感度最接近M或L的背景上,不同颜色的闪烁光之间仍存在显著的相位差异。相比之下,背景切换后不存在相位差异。背景切换程序带来的视锥细胞分离改善并不局限于闪烁测量:与稳定场相比,背景切换后受试者暂时呈现单色的光谱范围更广。