Manor D, Beyar R, Sideman S
Julius Silver Institute, Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa.
Am J Physiol. 1994 Jan;266(1 Pt 2):H310-8. doi: 10.1152/ajpheart.1994.266.1.H310.
The pressure-flow relationship of the coronary collaterals is investigated by using an electrical analog model that combines the coronary epicardial arteries with the nonlinear characteristics of the intramyocardial circulation. The study aims to examine some controversial issues concerning the collateral circulation, including the transmural distribution of the collaterals, the distensibility of the collateral vessels (whether rigid or complaint), the effects of microcirculatory embolization, the collateral zero-flow pressure, and the nonlinearity of the collateral pressure-flow relationship. The study is carried out by simulating and comparing two basic experimental set-ups in which a coronary artery is ligated and the retrograde flow serves as an index of collateral flow. In the first "free-flow" setup, flow is allowed to bleed retrogradely against atmospheric pressure while perfusion pressure to the rest of the coronary arteries is varied over a wide range. In the second "back-pressure" setup, the coronary perfusion pressure is maintained at the control levels while the back pressure to the retrograde flow in the excised artery is varied. According to the analysis, the nonlinear pressure-flow relationships depend heavily on the experimental setup and are a function of the distensibility of the collaterals, which are distributed mainly on the epicardial surface, and the nonlinear contraction characteristics of the myocardium. The measured retrograde flow tends to underestimate the total collateral flow for the back-pressure setup because of antegrade flow escape.
通过使用一种电模拟模型来研究冠状动脉侧支循环的压力-流量关系,该模型将冠状动脉心外膜动脉与心肌内循环的非线性特征相结合。本研究旨在探讨一些关于侧支循环的争议性问题,包括侧支的透壁分布、侧支血管的可扩张性(是刚性还是顺应性)、微循环栓塞的影响、侧支零流量压力以及侧支压力-流量关系的非线性。该研究通过模拟和比较两种基本实验设置来进行,在这两种设置中,冠状动脉被结扎,逆行血流作为侧支血流的指标。在第一个“自由流”设置中,血流在大气压下逆行流出,同时对冠状动脉其余部分的灌注压力在很宽的范围内变化。在第二个“背压”设置中,冠状动脉灌注压力保持在对照水平,同时对离体动脉中逆行血流的背压发生变化。根据分析,非线性压力-流量关系在很大程度上取决于实验设置,并且是侧支可扩张性的函数,侧支主要分布在心外膜表面,同时也是心肌非线性收缩特征的函数。对于“背压”设置,由于顺行血流逸出,测得的逆行血流往往会低估总的侧支血流。