Performance of the Reflotron and the Seralyzer in primary health care.

作者信息

Thue G, Sandberg S

机构信息

Department of Public Health and Primary Health Care, University of Bergen, Norway.

出版信息

Scand J Clin Lab Invest. 1993 May;53(3):253-61. doi: 10.1080/00365519309088417.

DOI:10.1080/00365519309088417
PMID:8316753
Abstract

Results from an external quality control of 212 Reflotron and 19 Seralyzer primary care users are presented and compared with performance in 60 hospital laboratories. Respondent deviation was assessed by testing for differences in the distribution of individual deviations from an assigned value for hospital laboratories, or from a general average of the measurement procedure for the Reflotron or the Seralyzer users respectively. Respondent deviation in the Reflotron group matched hospital laboratory deviation, whereas deviation in the Seralyzer group was larger for aspartate aminotransferase, cholesterol and potassium. Seralyzer deviation was larger compared with Reflotron deviation. Imprecision was better in the hospital group than in the Reflotron group for alanine aminotransferase, aspartate aminotransferase, bilirubin, and creatinine whereas Reflotron users performed better than hospitals and Seralyzer users for uric acid; the Seralyzer group was inferior to hospitals for aspartate amino-transferase and potassium. The analytical quality of a subgroup of 138 Reflotron and 18 Seralyzer primary care users was assessed and these users were divided into 'good' and 'other' categories. Good performance was associated independently with use of the Reflotron, with operation by laboratory educated personnel, and with doing comparably few analyses per week. We conclude that the Reflotron is suitable for primary case use whereas the Seralyzer is less suitable.

摘要

相似文献

1
Performance of the Reflotron and the Seralyzer in primary health care.
Scand J Clin Lab Invest. 1993 May;53(3):253-61. doi: 10.1080/00365519309088417.
2
Performance of dry-chemistry instruments in primary health care.基层医疗卫生机构中干式化学分析仪的性能
Scand J Clin Lab Invest. 1989 Sep;49(5):483-8. doi: 10.1080/00365518909089125.
3
A multicentre evaluation of the Ektachem DT60-, Reflotron- and Seralyzer III systems.对Ektachem DT60、Reflotron和Seralyzer III系统的多中心评估。
Eur J Clin Chem Clin Biochem. 1992 Sep;30(9):547-83.
4
Comparison of hospital staff performance when using desk top analysers for "near patient" testing.使用台式分析仪进行“床边”检测时医院工作人员绩效的比较。
J Clin Pathol. 1988 Feb;41(2):223-5. doi: 10.1136/jcp.41.2.223.
5
Near-patient testing. Quality of laboratory test results obtained by non-technical personnel in a decentralized setting.床边检测。在分散式环境中由非技术人员获得的实验室检测结果的质量。
Am J Clin Pathol. 1988 Jun;89(6):797-801. doi: 10.1093/ajcp/89.6.797.
6
Desktop analysers: quality of results obtained by medical office personnel.台式分析仪:医疗办公人员获得的结果质量
CMAJ. 1988 Mar 15;138(6):517-20.
7
Audit of near patient cholesterol testing in occupational health clinics.职业健康诊所即时检测胆固醇情况的审计
Occup Med (Lond). 1993 Feb;43(1):23-6. doi: 10.1093/occmed/43.1.23.
8
Comparison of the use of a dry chemistry analyser in primary care in Norway and the United Kingdom.挪威和英国基层医疗中干式化学分析仪使用情况的比较。
Br J Gen Pract. 1993 Jan;43(366):10-4.
9
Dry chemistry: an assessment of the BCL Reflotron system.
Med Lab Sci. 1990 Oct;47(4):263-71.
10
Cholesterol assays in the Seralyzer instrument.Seralyzer仪器中的胆固醇检测
J Clin Lab Anal. 1989;3(4):232-5. doi: 10.1002/jcla.1860030407.