Suppr超能文献

用于单光子发射计算机断层扫描通气肺显像的99锝标记α-D-葡萄糖1-磷酸气雾剂的评估

Evaluation of 99Tcm-labelled alpha-D-glucose 1-phosphate aerosols for SPECT ventilation lung imaging.

作者信息

Ercan M T, Ulutunçel N, Naldöken S

机构信息

Department of Nuclear Medicine, Hacettepe University, Faculty of Medicine, Ankara, Turkey.

出版信息

Nucl Med Commun. 1993 Jun;14(6):433-8.

PMID:8321483
Abstract

The purpose of the present investigation was to evaluate 99Tcm-labelled alpha-D-glucose 1-phosphate (GP) aerosols for single photon emission computed tomographic (SPECT) ventilation lung imaging in comparison to 99Tcm-diethylenetriaminepentaacetate (DTPA) aerosols. Ten normal nonsmoking male volunteers (aged 20-30 years) were included in this study after obtaining their informed consent. 99Tcm-GP, 30 mCi, in 2 ml was placed in the nebulizer (Venticis II) and inhalation continued for 5 min of normal breathing with oxygen flowing through. In 10 subjects dynamic images were obtained from the posterior position for 90 min with 45 frames on a 64 x 64 matrix by the use of a gamma camera. At the end of the dynamic study planar images of the lung (anterior, posterior and laterals) were recorded. Decay corrected clearance curves and kep values were obtained by the pulmonary epithelial programme and T1/2 values were calculated. The same procedure was followed by the use of 99Tcm-DTPA in the same subjects 2 weeks later. SPECT studies of the lung were performed in five subjects after inhalation of 99Tcm-GP aerosols. Clearance curves were monoexponential. The difference in T1/2 values between the right and left lungs was statistically insignificant (P > 0.10). The mean T1/2 values were 316.5 +/- 44.7 and 80.8 +/- 13.4 min for 99Tcm-GP and 99Tcm-DTPA, respectively. The difference was significant (P < 0.0005). On scintigraphic images 99Tcm-GP showed high alveolar deposition and low adhesion to major airways like 99Tcm-DTPA. However, it is preferred to 99Tcm-DTPA for SPECT studies because of its prolonged pulmonary clearance.

摘要

本研究的目的是评估99锝标记的α-D-葡萄糖1-磷酸(GP)气雾剂用于单光子发射计算机断层扫描(SPECT)肺通气成像,并与99锝-二乙三胺五乙酸(DTPA)气雾剂进行比较。在获得10名年龄在20至30岁之间的正常非吸烟男性志愿者的知情同意后,将其纳入本研究。将2 ml含30 mCi的99锝-GP置于雾化器(Venticis II)中,在有氧气流通的情况下,正常呼吸持续吸入5分钟。对10名受试者使用γ相机从后位获取90分钟的动态图像,矩阵为64×64,共45帧。在动态研究结束时,记录肺部的平面图像(前位、后位和侧位)。通过肺上皮程序获得衰变校正清除曲线和kep值,并计算T1/2值。两周后,对同一受试者使用99锝-DTPA,采用相同程序。在5名受试者吸入99锝-GP气雾剂后进行肺部SPECT研究。清除曲线为单指数曲线。左右肺T1/2值的差异无统计学意义(P>0.10)。99锝-GP和99锝-DTPA的平均T1/2值分别为316.5±44.7分钟和80.8±13.4分钟。差异具有统计学意义(P<0.0005)。在闪烁图像上,99锝-GP显示出与99锝-DTPA一样高的肺泡沉积和对主要气道的低粘附性。然而,由于其肺部清除时间延长,在SPECT研究中它比99锝-DTPA更受青睐。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验