Suppr超能文献

在青光眼性视野缺损检测中,眼动视野计与Humphrey视野分析的比较。

Oculokinetic perimetry compared with Humphrey visual field analysis in the detection of glaucomatous visual field loss.

作者信息

Wishart P K

机构信息

St. Paul's Eye Unit, Royal Liverpool University Hospital, UK.

出版信息

Eye (Lond). 1993;7 ( Pt 1):113-21. doi: 10.1038/eye.1993.24.

Abstract

The ability of oculokinetic perimetry (OKP) to detect glaucomatous central visual field loss was assessed by comparison with the results of Humphrey visual field analysis (HVFA) in a group of patients attending a glaucoma clinic. Fifty-six patients with stable visual fields and good reliability indices on previous automated perimetry examinations underwent programmes 24-1 or 24-2 of the Humphrey visual field analyser and the results compared with those of a field test using a hand-held OKP chart. Forty-three patients had a glaucomatous visual field defect demonstrated by HVFA, and 35 showed a defect to OKP. Thirteen patients were shown to have normal fields on HVFA, and in 21 patients the OKP test was normal. Comparison of the two test results showed that of the 35 patients with abnormal OKP tests, in 26 the result was a true positive (HVFA also abnormal) and in 9 a false positive (HVFA normal). In the 21 patients with negative OKP tests the results were judged false negatives in 13 (HFVA showed glaucomatous visual field loss) while in 8 they were true negatives (HVFA normal). Therefore the sensitivity of OKP for the detection of glaucomatous visual field loss was 60.5% and the specificity for the identification of individuals with glaucomatous visual field loss was 61.5%. In the 26 patients with true positive results there were 36 eyes with positive OKP charts corresponding to defects on HVFA. Correlation of the number of defects on OKP with the mean deviation and corrected pattern standard deviation of their respective HVFA charts showed a near linear correlation.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

通过与一组青光眼门诊患者的 Humphrey 视野分析(HVFA)结果相比较,评估了眼动视野计(OKP)检测青光眼性中心视野缺损的能力。56 例视野稳定且之前自动视野检查可靠性指标良好的患者接受了 Humphrey 视野分析仪的 24-1 或 24-2 程序检查,并将结果与使用手持式 OKP 图表进行的视野测试结果相比较。43 例患者经 HVFA 显示有青光眼性视野缺损,35 例经 OKP 显示有缺损。13 例患者经 HVFA 显示视野正常,21 例患者 OKP 测试正常。两种测试结果的比较显示,在 35 例 OKP 测试异常的患者中,26 例结果为真阳性(HVFA 也异常),9 例为假阳性(HVFA 正常)。在 21 例 OKP 测试阴性的患者中,13 例结果被判定为假阴性(HFVA 显示有青光眼性视野缺损),8 例为真阴性(HVFA 正常)。因此,OKP 检测青光眼性视野缺损的敏感度为 60.5%,识别青光眼性视野缺损个体的特异度为 61.5%。在 26 例真阳性结果的患者中,有 36 只眼的 OKP 图表呈阳性,对应于 HVFA 上的缺损。OKP 上缺损数量与其各自 HVFA 图表的平均偏差和校正模式标准差的相关性显示出近乎线性的关系。(摘要截短于 250 字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验