A small-volume voltammetric detection of 4-aminophenol (PAP) has been developed using an interdigitated array (IDA) microelectrode cell in order to apply the IDA to electrochemical enzyme immunoassay. The signal of PAP at the IDA was steady state, and its magnitude was amplified compared with that of the usual single electrode due to redox cycling of PAP between the two finger sets of the IDA. A linear relationship between PAP concentration and cathodic limiting current was obtained from 1 to 1000 microM, reproducibly. The minimum sample volume in the measurement was reduced to 800 nL. High sample throughput of less than 1-min detection time per sample was achieved on 2-10-microL PAP samples. This IDA cell was applied to the electrochemical enzyme immunoassay of mouse IgG. Alkaline phosphatase was used as the enzyme label. The mouse IgG concentration was evaluated by detecting the concentration of PAP, which is the product of enzymatic reaction of the substrate, 4-aminophenyl phosphate (PAPP). Anti-mouse IgG was covalently immobilized on the glass surface of the small-volume immunowells by carbodiimide coupling. The assay range was 10-1000 ng/mL using 10-microL sample and 20-microL substrate solutions.
为了将叉指阵列(IDA)应用于电化学酶免疫分析,已开发出一种使用IDA微电极池对4-氨基苯酚(PAP)进行小体积伏安检测的方法。PAP在IDA处的信号为稳态,由于PAP在IDA的两组指状电极之间进行氧化还原循环,其信号强度与普通单电极相比有所放大。在1至1000微摩尔范围内,PAP浓度与阴极极限电流之间呈现可重复的线性关系。测量时的最小样品体积减少至800纳升。对于2至10微升的PAP样品,实现了每个样品检测时间少于1分钟的高样品通量。该IDA池应用于小鼠IgG的电化学酶免疫分析。使用碱性磷酸酶作为酶标记物。通过检测PAP的浓度来评估小鼠IgG的浓度,PAP是底物4-氨基苯磷酸酯(PAPP)酶促反应的产物。抗小鼠IgG通过碳二亚胺偶联共价固定在小体积免疫孔的玻璃表面。使用10微升样品和20微升底物溶液时,检测范围为10至1000纳克/毫升。