Yu H Y, Liau J K
School of Pharmacy, National Taiwan University, Taipei.
J Chromatogr. 1993 May 19;615(1):77-81. doi: 10.1016/0378-4347(93)80292-c.
A rapid, accurate and sensitive gas chromatographic method is described for measuring plasma concentrations of propofol. The technique required only 200 microliters of plasma and a single extraction process, using chloroform containing pentadecane (500 ng/ml) as an internal standard. Quantitation was achieved on an SGE BP-1 fused-silica capillary column (25 m x 0.33 mm I.D., 0.5 micron film thickness) with flame ionization detector. The peak response was linear over a wide concentration range (10-10,000 ng/ml) and the limit of quantitation was 10 ng/ml. The absolute recoveries were over 96% (n = 3). The method is applicable for both research and routine plasma level monitoring.
本文描述了一种快速、准确且灵敏的气相色谱法,用于测定血浆中丙泊酚的浓度。该技术仅需200微升血浆,并采用单次萃取过程,使用含有十五烷(500纳克/毫升)作为内标的氯仿。定量分析在SGE BP-1熔融石英毛细管柱(25米×0.33毫米内径,0.5微米膜厚)上进行,配备火焰离子化检测器。在较宽的浓度范围(10 - 10,000纳克/毫升)内,峰响应呈线性,定量限为10纳克/毫升。绝对回收率超过96%(n = 3)。该方法适用于研究和常规血浆水平监测。