使用H2(15)O正电子发射断层扫描技术测量人体静息脑血流量的可重复性。

Reproducibility of resting cerebral blood flow measurements with H2(15)O positron emission tomography in humans.

作者信息

Matthew E, Andreason P, Carson R E, Herscovitch P, Pettigrew K, Cohen R, King C, Johanson C E, Paul S M

机构信息

Neuroscience Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland.

出版信息

J Cereb Blood Flow Metab. 1993 Sep;13(5):748-54. doi: 10.1038/jcbfm.1993.95.

Abstract

Two consecutive measurements of resting CBF were carried out in normal volunteers (n = 25) using H2(15)O positron emission tomography. Absolute whole-brain blood flow (WBBF; ml 100 g-1 min-1, mean +/- SD) for the first (40.3 +/- 6.4) and second (39.3 +/- 6.5) measurements was not significantly different (mean % difference 2.3 +/- 8.7). Analysis of regions of interest showed no significant differences in absolute regional CBF (rCBF) and normalized (rCBF/WBBF) rCBF. Left-right differences were also not significant. These data demonstrate the reproducibility of resting CBF measurements in normal humans.

摘要

使用H2(15)O正电子发射断层扫描技术,对25名正常志愿者进行了两次连续的静息脑血流量(CBF)测量。第一次测量的全脑绝对血流量(WBBF;ml 100 g-1 min-1,平均值±标准差)为(40.3±6.4),第二次测量为(39.3±6.5),两者无显著差异(平均百分比差异为2.3±8.7)。感兴趣区域分析显示,绝对局部脑血流量(rCBF)和归一化(rCBF/WBBF)rCBF均无显著差异。左右差异也不显著。这些数据证明了正常人类静息CBF测量的可重复性。