Suppr超能文献

采用自动柱切换的高效液相色谱法测定人血浆中的双氯芬酸。

High-performance liquid chromatographic determination of diclofenac in human plasma using automated column switching.

作者信息

Miller R B

机构信息

Analytical Research Center, L.A.B. Bio-Research International Inc., Senneville, Montreal, Quebec, Canada.

出版信息

J Chromatogr. 1993 Jul 2;616(2):283-90. doi: 10.1016/0378-4347(93)80396-l.

Abstract

A validated high-performance liquid chromatographic procedure employing ultraviolet detection for the analysis of diclofenac in human plasma is reported. The method is rapid and, coupled with column switching, leads to a sensitive, accurate and reproducible assay. The retention times of diclofenac and the internal standard (4'-methoxydiclofenac, CGP-4287) are 6.4 and 7.6 min, respectively. The peak height versus plasma concentration is linear over the range 5.0-2000 ng/ml with a detection limit below 2.5 ng/ml. The mean absolute recovery of diclofenac using the described assay is 96.5% (n = 24). The inter- and intra-day accuracy and precision are within 8.3% of the actual values for all concentrations investigated. Furthermore, this procedure is applied to assess the pharmacokinetics of a single 75-mg oral dose of diclofenac sodium.

摘要

报道了一种经过验证的高效液相色谱法,该方法采用紫外检测来分析人血浆中的双氯芬酸。该方法快速,结合柱切换技术,可实现灵敏、准确且可重复的测定。双氯芬酸和内标物(4'-甲氧基双氯芬酸,CGP-4287)的保留时间分别为6.4分钟和7.6分钟。峰高与血浆浓度在5.0 - 2000 ng/ml范围内呈线性关系,检测限低于2.5 ng/ml。使用所述测定法时,双氯芬酸的平均绝对回收率为96.5%(n = 24)。对于所有研究浓度,日内和日间的准确度和精密度均在实际值的8.3%以内。此外,该方法用于评估单次口服75 mg双氯芬酸钠的药代动力学。