血细胞计数器白细胞黏附抑制技术。

Hemocytometer leukocyte adherence inhibition technique.

作者信息

Maluish A E, Halliday W J

出版信息

Cancer Res. 1979 Feb;39(2 Pt 2):625-6.

PMID:83916
Abstract

The hemocytometer leukocyte adherence inhibition technique was employed in a criss-cross experimental design with two cancer patients (melanoma and colon carcinoma) and the corresponding tumor extracts. These extracts had been repeatedly tested for specific reactivity and lyophilized before transport to the workshop. The patients' leukocytes were mixed singly with each extract in the presence of normal serum, and the adherences of the cells were determined in hemocytometer chambers. Actual cell counts (total cells before washing and adherent cells after washing) are given in detail for the first time. Blood samples and reaction mixtures were coded by an independent observer. Determination of mean % adherence (+/- S.E.) showed that the melanoma patient's leukocytes (original adherence 70.8 +/- 2.8) reached with the melanoma extract (40.7 +/- 2.9; p less than 0.001) but not significantly with the colon carcinoma extract (61.5 +/- 4.1; p greater than 0.05). Similarly, the colon carcinoma patient's leukocytes (original adherence 68.6 +/- 2.7) reacted with the colon carcinoma extract (43.2 +/- 2.3; p less than 0.001) but adherence was not inhibited by the melanoma extract (76.9 +/- 2.6). The cancer patients were thus correctly identified with regard to tumor type in a simple blind trial.

摘要

血细胞计数器白细胞黏附抑制技术用于对两名癌症患者(黑色素瘤和结肠癌)及相应肿瘤提取物进行交叉实验设计。这些提取物在运往实验室之前,已反复检测其特异性反应性并进行了冻干处理。在正常血清存在的情况下,将患者的白细胞分别与每种提取物混合,并在血细胞计数器计数板中测定细胞的黏附情况。首次详细给出了实际细胞计数(洗涤前的总细胞数和洗涤后的黏附细胞数)。血液样本和反应混合物由一名独立观察者进行编码。平均黏附百分比(±标准误)的测定结果显示,黑色素瘤患者的白细胞(初始黏附率为70.8±2.8)与黑色素瘤提取物混合后黏附率降低(40.7±2.9;p<0.001),但与结肠癌提取物混合后黏附率无显著变化(61.5±4.1;p>0.05)。同样,结肠癌患者的白细胞(初始黏附率为68.6±2.7)与结肠癌提取物混合后黏附率降低(43.2±2.3;p<0.001),但与黑色素瘤提取物混合后黏附率未受抑制(76.9±2.6)。因此,在一项简单的盲法试验中,能够正确识别癌症患者的肿瘤类型。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验