We describe a time-resolved fluoroimmunoassay (TRFIA) for recombinant human interleukin-3 (IL-3). The assay design uses two different monoclonal anti-IL-3 antibodies, giving a two-site immunometric assay. The TRFIA for IL-3 is a direct adaptation from our existing ELISA for IL-3. By using the same assay configuration and exchanging a europium-streptavidin conjugate for alkaline phosphatase-streptavidin, we were able to minimize the time required to develop a TRFIA, but still increase the working range of the TRFIA over the ELISA by 20-fold. The limit of detection is 5 ng/L, with the limits of quantification set at 5 and 30,000 ng/L human plasma.
我们描述了一种用于重组人白细胞介素-3(IL-3)的时间分辨荧光免疫分析(TRFIA)方法。该分析方法设计使用两种不同的抗IL-3单克隆抗体,构成双位点免疫分析。IL-3的TRFIA是直接改编自我们现有的IL-3酶联免疫吸附测定(ELISA)。通过使用相同的分析配置,并将铕-链霉亲和素缀合物换成碱性磷酸酶-链霉亲和素,我们能够将开发TRFIA所需的时间降至最短,但仍使TRFIA的工作范围比ELISA扩大了20倍。检测限为5 ng/L,人血浆中的定量限设定为5和30,000 ng/L。