Rojanapongpun P, Morrison B, Drance S M
Department of Ophthalmology and Epidemiology, Faculty of Medicine, and University Hospital, University of British Columbia, Vancouver, Canada.
Br J Ophthalmol. 1993 Jan;77(1):22-4. doi: 10.1136/bjo.77.1.22.
Transcranial Doppler ultrasound measurements of ophthalmic artery velocity were made on 88 patients predominantly suffering from glaucoma. Of the four observed parameters, peak velocity, mean-enveloped velocity, diastolic velocity, and resistivity index, the latter was found to be the most reproducible (CV = 5.2%). The variability between patients was approximately twice that of the variability between consecutive measurements. Measurement error appeared to decrease as the operator gained experience.