Are buckling force measurements reliable in nocturnal penile tumescence studies?

作者信息

Nofzinger E A, Fasiczka A L, Thase M E, Reynolds C F, Frank E, Jennings J R, Garamoni G L, Matzzie J V, Kupfer D J

机构信息

Sleep and Chronobiology Center, University of Pittsburgh School of Medicine, Western Psychiatric Institute and Clinic, Pennsylvania 15213.

出版信息

Sleep. 1993 Feb;16(2):156-62.

PMID:8446836
Abstract

The study of nocturnal penile tumescence (NPT) is frequently used to evaluate male erectile dysfunction. Buckling force, a measure of rigidity, is an important part of this evaluation, but its reliability is unknown. Accordingly, we studied the reliability of buckling force measurement and the stability of "maximum buckling force" between consecutive NPT series repeated in the same subject. For individual subjects, we correlated buckling forces for separate episodes of sleep-related tumescence that were of comparable fullness (0-100%) as rated by a technician's visual estimates. For healthy control subjects, test-retest correlations were > 0.8 both within-night and across study series separated by an average of 70 weeks. In depressed men, correlations within nights were > 0.9, but fell to 0.64 across study series separated by an average of 21 weeks. Despite the high reliability of buckling force measurement, we found little stability of "maximum buckling force" between NPT series for individual subjects. Considerable variability in the maximum degree of penile rigidity was seen over time despite a constant level of reported daytime erectile function. We conclude that although penile rigidity is one of the more important variables in the assessment of male erectile dysfunction and can be measured reliably, the instability of maximum rigidity during sleep-related erections suggests that it is, at best, an imprecise correlate of daytime erectile function.

摘要

夜间阴茎勃起(NPT)的研究常用于评估男性勃起功能障碍。屈曲力作为一种硬度测量指标,是该评估的重要组成部分,但其可靠性尚不清楚。因此,我们研究了屈曲力测量的可靠性以及同一受试者连续NPT系列之间“最大屈曲力”的稳定性。对于个体受试者,我们将技术人员通过视觉估计评定为具有可比充盈度(0 - 100%)的与睡眠相关勃起的不同发作的屈曲力进行了关联。对于健康对照受试者,夜间内和平均间隔70周的不同研究系列之间的重测相关性均>0.8。在抑郁男性中,夜间内相关性>0.9,但在平均间隔21周的不同研究系列之间降至0.64。尽管屈曲力测量具有较高的可靠性,但我们发现个体受试者的NPT系列之间“最大屈曲力”的稳定性较差。尽管报告的日间勃起功能水平恒定,但随着时间的推移,阴茎最大硬度程度存在相当大的变异性。我们得出结论,虽然阴茎硬度是评估男性勃起功能障碍中较为重要的变量之一,并且可以可靠地测量,但睡眠相关勃起期间最大硬度的不稳定性表明,它充其量只是日间勃起功能的一个不精确的相关指标。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验