Khalfayan E E, Sharkey P F, Alexander A H
Department of Orthopaedic Surgery, Naval Hospital, Oakland, California.
Orthop Rev. 1993 Feb;22(2):259-62.
There have been many modifications of the proximal tibial osteotomy since it was initially described by Jackson in 1958. The trend toward rigid internal fixation and early motion after osteotomy prompted the authors to develop a technique using cannulated screws for stabilization. This method is simple and quick, involves no soft-tissue dissection, and allows early postoperative motion.
自1958年杰克逊首次描述胫骨近端截骨术以来,该手术已有许多改进。截骨术后采用坚强内固定和早期活动的趋势促使作者研发一种使用空心螺钉进行固定的技术。这种方法简单快捷,无需进行软组织剥离,且允许术后早期活动。