Suppr超能文献

缩窄修复术后的无创长期随访。

Noninvasive long-term follow-up after coarctation repair.

作者信息

Kappetein P A, Guit G L, Bogers A J, Weeda H W, Zwinderman K H, Schönberger J P, Huysmans H A

机构信息

Department of Thoracic Surgery, University Hospital Leiden, The Netherlands.

出版信息

Ann Thorac Surg. 1993 May;55(5):1153-9. doi: 10.1016/0003-4975(93)90024-c.

Abstract

Thirty patients operated on for aortic coarctation while less than 3 years of age underwent magnetic resonance imaging, digital subtraction angiography, and bicycle exercise testing 14 to 33 years (mean, 22 years) after operation. Diameters of the aorta at the site of the anastomosis, of the distal arch, and of the aorta at the level of the diaphragm were measured in the images. Blood pressures were obtained from the right arm and leg before and after exercise. Patients were divided into three groups according to blood pressure data: group I, resting gradient less than 30 mm Hg and exercise gradient less than 50 mm Hg; group II, resting gradient less than 30 mm Hg and exercise gradient greater than 50 mm Hg; and group III, resting gradient 30 mm Hg or greater. A control group underwent the same test. The frequency of hypertensive patients was greater in groups II (58%) and III (100%) than in group I (20%). The anastomosis/descending aorta ratio seen in digital subtraction angiograms was smaller in group II and III patients. Exercise blood pressure gradient correlated significantly (r = -0.48; p = 0.009) with anastomosis/descending aorta ratio in digital subtraction angiograms but not in magnetic resonance images. Twenty of 30 patients (67%) had a significant anatomic narrowing at the site of the anastomosis. Blood pressure data correlated with diameters measured in digital subtraction angiograms but not with diameters measured in magnetic resonance images.

摘要

30例3岁以下接受主动脉缩窄手术的患者在术后14至33年(平均22年)接受了磁共振成像、数字减影血管造影和自行车运动试验。在图像中测量吻合部位、主动脉弓远端以及膈肌水平处主动脉的直径。在运动前后测量右臂和腿部的血压。根据血压数据将患者分为三组:第一组,静息压差小于30 mmHg且运动压差小于50 mmHg;第二组,静息压差小于30 mmHg且运动压差大于50 mmHg;第三组,静息压差为30 mmHg或更高。对照组进行相同的测试。第二组(58%)和第三组(100%)高血压患者的频率高于第一组(20%)。数字减影血管造影中可见的吻合口/降主动脉比值在第二组和第三组患者中较小。运动血压梯度与数字减影血管造影中的吻合口/降主动脉比值显著相关(r = -0.48;p = 0.009),但与磁共振图像无关。30例患者中有20例(67%)在吻合部位存在明显的解剖学狭窄。血压数据与数字减影血管造影中测量的直径相关,但与磁共振图像中测量的直径无关。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验