Suppr超能文献

正常成年受试者无支撑手臂运动耐力测量中的仪器开发。

Instrument development in the measurement of unsupported arm exercise endurance in normal adult subjects.

作者信息

Breslin E H, Adams E, Lutz A, Roy C

机构信息

University of California Davis, Medical Center, Center for Nursing Research.

出版信息

Arch Phys Med Rehabil. 1993 Jun;74(6):649-52. doi: 10.1016/0003-9993(93)90165-7.

Abstract

Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.

摘要

许多日常活动,从基本的个人护理到工作任务,都需要足够的无支撑手臂耐力(UAE)。我们开发了一种机电装置来测量UAE耐力。本研究的目的是在18名正常成年受试者(FEVI = 3.7L±0.78,FVC = 4.2L±0.74,FEV1/FVC = 1.1±0.08)中,针对两种手臂运动速率(中等和缓慢)对该仪器进行标准化。在运动前休息时以及在两种UAE速率的运动极限结束时,确定运动耐力极限以及以下代谢、通气和感觉反应:分钟通气量(Ve)、潮气量(VT)、呼吸频率(RR)、占空比(Ti/Ttot)、摄氧量(VO2)、二氧化碳产生量(VCO2)、吸气流量(VT/Ti)、心率(HR)以及呼吸困难(D)、呼吸努力(RE)和手臂疲劳(AF)的视觉模拟量表测量值(VAS)。在两种UAE速率的耐力极限时,与基线休息相比,VO2、VCO2、Ve、VT、RR、VT/Ti、HR、VAS-D、VAS-RE和VAS-AF均有显著增加。UAE时Ti/Ttot和SaO2无变化。中等强度运动时的峰值VO2、RR、Ve、VT/Ti和VAS-D显著高于缓慢UAE;与缓慢UAE速率相比,中等强度UAE的峰值HR有增加趋势。尽管存在这些差异,但两种UAE速率之间的耐力时间相似。这些数据提供了可用于评估慢性阻塞性肺疾病(COPD)患者UAE的标准。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验