• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Occurrence, extent, and implications of pressure waves during excimer laser ablation of normal arterial wall and atherosclerotic plaque.

作者信息

Haase K K, Hanke H, Baumbach A, Hassenstein S, Wehrmann M, Duda S, Rose C, von Münch W, Karsch K R

机构信息

Department of Medicine, University of Tübingen, Germany.

出版信息

Lasers Surg Med. 1993;13(3):263-70. doi: 10.1002/lsm.1900130302.

DOI:10.1002/lsm.1900130302
PMID:8515665
Abstract

Ablation of atherosclerotic plaque and normal arterial wall was performed using a Xenon-Chloride Excimer laser with a wave-length of 308 nm and a pulse duration of 115 ns. The light was transmitted via a 600 microns bare fibre and adjusted to an energy density of 3.5J/cm2. The acoustic signals generated by the laser pulse were measured with two types of hydrophones consisting of polyvinylidenefluoride with active diameters of 0.3 mm and 0.5 mm and recorded on a dual channel digital storage oscilloscope using either a 0.5 m coaxial cable or a broadband fibre-optic transmission system. Tissue was retrieved from nine cadaver human aortas and macroscopically classified as either normal or calcified atherosclerotic plaque. Histological analysis (Haematoxylin eosin, elastica van Gieson, and immunohistochemical staining) was carried out after the experiments to verify the macroscopic diagnosis and to correlate the acoustic responses with the tissue characteristics. For normal arterial wall, maximum peak pressure was 1.28 MPa +/- 0.85 MPa, rise time 163 ns +/- 43 ns, and pressure increase 8.2k Pa +/- 5.4k Pa/ns. For calcified, atheromatous segments, a maximum peak pressure of 2.02 MPa +/- 1.16 MPa, a rise time of 69.9 ns +/- 25.8 ns, and a pressure increase of 32.3 kPa +/- 21.3 kPa/ns was found. Statistical analysis showed a significant shorter rise time (P < 0.0001) and a higher pressure increase (P < 0.0001) for calcified tissue in comparison to normal arterial wall, whereas maximum pressures alone did not allow a differentiation of tissue characteristics. Several hundred kPa are generated during Excimer laser ablation.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Occurrence, extent, and implications of pressure waves during excimer laser ablation of normal arterial wall and atherosclerotic plaque.
Lasers Surg Med. 1993;13(3):263-70. doi: 10.1002/lsm.1900130302.
2
[In vitro studies of shock wave effects during ablation of normal and atherosclerotic vascular wall by excimer laser].
Z Kardiol. 1993 Feb;82(2):87-93.
3
Perspectives of coronary excimer laser angioplasty: multiplexing, saline flushing, and acoustic ablation control.
Lasers Surg Med. 1997;21(1):72-8. doi: 10.1002/(sici)1096-9101(1997)21:1<72::aid-lsm11>3.0.co;2-b.
4
Atherosclerotic tissue analysis by time-resolved XeCl excimer laser reflectometry.通过时间分辨XeCl准分子激光反射测量法进行动脉粥样硬化组织分析。
Lasers Surg Med. 1993;13(3):279-83. doi: 10.1002/lsm.1900130304.
5
Occurrence and magnitude of pressure waves during Er:YAG laser ablation of atherosclerotic tissue: comparison to XeCl excimer laser ablation.铒钇铝石榴石激光消融动脉粥样硬化组织时压力波的发生情况及强度:与氙氯准分子激光消融的比较
Lasers Surg Med. 1996;19(3):273-83. doi: 10.1002/(SICI)1096-9101(1996)19:3<273::AID-LSM3>3.0.CO;2-P.
6
XeCl laser ablation of atherosclerotic aorta: luminescence spectroscopy of ablation products.
Lasers Surg Med. 1993;13(2):168-78. doi: 10.1002/lsm.1900130204.
7
In vitro ablation of normal and diseased vascular tissue by a fiber-transmitted holmium laser.
Invest Radiol. 1991 Jul;26(7):660-4. doi: 10.1097/00004424-199107000-00006.
8
Characteristics of 308 nm excimer laser activated arterial tissue photoemission under ablative and non-ablative conditions.308纳米准分子激光在消融和非消融条件下激活动脉组织光发射的特征
Lasers Surg Med. 1989;9(6):556-71. doi: 10.1002/lsm.1900090605.
9
Analysis of particle size generated during plaque ablation with a flashlamp pumped pulsed dye laser.闪光灯泵浦脉冲染料激光斑块消融过程中产生的颗粒大小分析。
Cardiovasc Intervent Radiol. 1995 Jan-Feb;18(1):35-8. doi: 10.1007/BF02807353.
10
In vitro evaluation of ablation parameters of normal and fibrous aorta using smooth excimer laser coronary angioplasty.使用准分子激光冠状动脉成形术对正常和纤维化主动脉消融参数的体外评估。
Lasers Surg Med. 1993;13(6):618-24. doi: 10.1002/lsm.1900130605.

引用本文的文献

1
Smooth excimer laser coronary angioplasty (SELCA) and conventional excimer laser angioplasty: Comparison of vascular injury and smooth muscle cell proliferation.准分子激光冠状动脉成形术(SELCA)与传统准分子激光血管成形术:血管损伤与平滑肌细胞增殖的比较。
Lasers Med Sci. 1997 Dec;12(4):328-35. doi: 10.1007/BF02767155.
2
XeCl laser ablation of biocompatible PTFE studied by photothermal beam deflection.用光热束偏转法研究生物相容性聚四氟乙烯的 XeCl 激光烧蚀
Lasers Med Sci. 1997 Dec;12(4):313-9. doi: 10.1007/BF02767153.
3
Photoacoustic Fibrinolysis: Pulsed-Wave, Mid-Infrared Laser-Clot Interaction.
光声纤维蛋白溶解:脉冲波、中红外激光与血凝块的相互作用。
J Thromb Thrombolysis. 1996;3(3):209-214. doi: 10.1007/BF00181663.