• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Perspectives of coronary excimer laser angioplasty: multiplexing, saline flushing, and acoustic ablation control.

作者信息

Haase K K, Rose C, Duda S, Baumbach A, Oberhoff M, Anthanasiadis A, Karsch K R

机构信息

Department of Medicine, University of Tübingen, Germany.

出版信息

Lasers Surg Med. 1997;21(1):72-8. doi: 10.1002/(sici)1096-9101(1997)21:1<72::aid-lsm11>3.0.co;2-b.

DOI:10.1002/(sici)1096-9101(1997)21:1<72::aid-lsm11>3.0.co;2-b
PMID:9228643
Abstract

BACKGROUND AND OBJECTIVE

Bubble formation, pressure wave generation, and cavitations constitute major factors influencing the outcome of clinical Excimer laser angioplasty. Thus, the rationale of this study was to determine the extent of pressure waves occurring during excimer laser ablation and to discuss possibilities that allow a less traumatic plaque removal in the coronary circulation.

STUDY DESIGN/MATERIALS AND METHODS: Conventional and experimental Xenon-Chlorid-Excimer lasers emitting light at a wave-length of 308 nm and a pulse duration of 115 ns were used for testing of signals. Whereas the conventional excimer laser light source transmits light through all fibers of a 1.7 mm laser catheter simultaneously, the prototype excimer laser divides the laser beam into several areas of uniform energy fluence by scanning the beam from one section to the other using the intermission between two laser discharges. Hydrophones consisting of piezoelectric films detected the acoustic signals, which were obtained on normal arterial wall and atherosclerotic plaque.

RESULTS

Multiplexing decreases maximum pressures for both normal arterial wall and calcified plaque significantly, whereas pressure rise time remains comparable. During ablation of pure blood, a linear increase of peak pressures of 1 MPa at 10 mJ/mm2 to 7.5 MPa at 50 mJ/mm2 is found. Contrast media intensifies the extent of pressure wave formation. At 20 mJ/mm2, 60% contrast media added to blood results in an increase of maximum pressures from 1.5 MPa up to 5 MPa. Dilution with saline solution is effective; however, high concentrations of > 90% are required to achieve a significant pressure wave reduction.

CONCLUSION

Peak pressures of several thousand kPa occur during excimer laser ablation of contrast media, blood, calcified plaque, and normal arterial wall in a decreasing order. Multiplexing and saline flushing are capable of reducing the intensity of the generated acoustic signals during tissue ablation. It has to be taken into consideration, however, that high concentrations of saline solution are necessary to achieve a significant reduction of peak pressures.

摘要

相似文献

1
Perspectives of coronary excimer laser angioplasty: multiplexing, saline flushing, and acoustic ablation control.
Lasers Surg Med. 1997;21(1):72-8. doi: 10.1002/(sici)1096-9101(1997)21:1<72::aid-lsm11>3.0.co;2-b.
2
Occurrence, extent, and implications of pressure waves during excimer laser ablation of normal arterial wall and atherosclerotic plaque.
Lasers Surg Med. 1993;13(3):263-70. doi: 10.1002/lsm.1900130302.
3
Formation of pressure waves during in vitro excimer laser irradiation in whole blood and the effect of dilution with contrast media and saline.
Lasers Surg Med. 1994;14(1):3-6. doi: 10.1002/lsm.1900140104.
4
[In vitro studies of shock wave effects during ablation of normal and atherosclerotic vascular wall by excimer laser].
Z Kardiol. 1993 Feb;82(2):87-93.
5
Development of a new technique for reducing pressure pulse generation during 308-nm excimer laser coronary angioplasty.一种用于减少308纳米准分子激光冠状动脉成形术期间压力脉冲产生的新技术的开发。
Cathet Cardiovasc Diagn. 1995 Jan;34(1):15-22. doi: 10.1002/ccd.1810340306.
6
Intraluminal vapor bubble induced by excimer laser pulse causes microsecond arterial dilation and invagination leading to extensive wall damage in the rabbit.
Circulation. 1993 Apr;87(4):1258-63. doi: 10.1161/01.cir.87.4.1258.
7
Occurrence and magnitude of pressure waves during Er:YAG laser ablation of atherosclerotic tissue: comparison to XeCl excimer laser ablation.铒钇铝石榴石激光消融动脉粥样硬化组织时压力波的发生情况及强度:与氙氯准分子激光消融的比较
Lasers Surg Med. 1996;19(3):273-83. doi: 10.1002/(SICI)1096-9101(1996)19:3<273::AID-LSM3>3.0.CO;2-P.
8
Effect of intracoronary saline infusion on dissection during excimer laser coronary angioplasty: a randomized trial. The Percutaneous Excimer Laser Coronary Angioplasty (PELCA) Investigators.
J Am Coll Cardiol. 1995 Nov 1;26(5):1264-9. doi: 10.1016/0735-1097(95)00330-4.
9
Percutaneous coronary excimer laser-assisted angioplasty: initial multicenter experience in 141 patients.经皮冠状动脉准分子激光辅助血管成形术:141例患者的初步多中心经验。
J Am Coll Cardiol. 1991 May;17(6 Suppl B):169B-173B. doi: 10.1016/0735-1097(91)90954-8.
10
Autofluorescence spectroscopy using a XeCl excimer laser system for simultaneous plaque ablation and fluorescence excitation.使用XeCl准分子激光系统进行同时斑块消融和荧光激发的自体荧光光谱学。
Lasers Surg Med. 1994;14(3):238-48. doi: 10.1002/lsm.1900140306.