Suppr超能文献

人眼死后取出的硅水凝胶人工晶状体的病理学研究

Pathology of silicone intraocular lenses in human eyes obtained postmortem.

作者信息

Blotnick C A, Powers T P, Newland T, McMillan T, Bluestein E L, Apple D J

机构信息

Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston 29425, USA.

出版信息

J Cataract Refract Surg. 1995 Jul;21(4):447-52. doi: 10.1016/s0886-3350(13)80538-x.

Abstract

The increased use of phacoemulsification and small incision surgery has led to interest in a soft intraocular lens (IOL) for implantation after cataract extraction. We present the pathologic findings of seven eyes obtained postmortem from five patients with silicone IOLs. Length of implantation ranged from 6 weeks to 13 months. There was symmetric bag-bag fixation in all cases. Two IOLs had distorted and compressed polypropylene loops, resulting in decentration. The silicone IOL appeared to be well tolerated in all cases.

摘要

超声乳化和小切口手术使用的增加引发了对白内障摘除术后植入软性人工晶状体(IOL)的兴趣。我们展示了5例植入硅胶IOL患者死后获得的7只眼的病理结果。植入时间从6周至13个月不等。所有病例均为对称的囊袋内固定。2个IOL的聚丙烯袢发生扭曲和压缩,导致偏心。在所有病例中,硅胶IOL似乎耐受性良好。