Suppr超能文献

Use of rapid kinetics methods to study the assembly of the diferric-tyrosyl radical cofactor of E. coli ribonucleotide reductase.

作者信息

Bollinger J M, Tong W H, Ravi N, Huynh B H, Edmondson D E, Stubbe J A

机构信息

Department of Chemistry, Massachusetts Institute of Technology, Cambridge 02139, USA.

出版信息

Methods Enzymol. 1995;258:278-303. doi: 10.1016/0076-6879(95)58052-2.

Abstract

The SF-Abs, RFQ-EPR, and RFQ-Möss data on the R2 reconstitution reaction are all consistent with the mechanism of Scheme I, in which the intermediate X is the immediate precursor to the product cofactor, and illustrate how the continuous SF approach and the discontinuous RFQ methods can be complementary. Given the inherent differences in the methods, it should not be taken for granted that data from the two will be consistent. A number of problems can be associated with the RFQ approach. For example, isopentane could conceivably interfere with or alter the chemistry to be studied. A second potential problem involves temperature-dependent equilibria among different intermediate species. This problem has been encountered by Dooley et al. with the 6-hydroxydopa-requiring protein, plasma amine oxidase and was previously observed with the adenosylcobalamin-dependent ribonucleotide reductase by Blakley and co-workers. This potential complication should be considered when discrepancies arise between SF and RFQ data and in low temperature structural studies of reactive intermediates in general. Each of the three methods employed can yield time-resolved quantitation of reaction components. In this regard, SF-Abs has the disadvantage of poor resolution, such that quantitation of individual components most often requires sophisticated mathematical analysis. Obvious advantages to the RFQ-Möss method are the presence of an internal standard (the known amount of 57Fe being proportional to the total absorption area) and the spectroscopic activity of all reaction components which contain iron. In our hands, quantitation by RFQ-EPR was most problematic and least reproducible. This irreproducibility most likely relates to heterogeneity among samples in terms of volume and density. As discussed in detail by Ballou and Palmer, the packing factor, which relates to the fraction of a sample made up by the reaction solution (the remainder being frozen isopentane), is dependent on the investigator. Given this caveat, it is not surprising that the RFQ-EPR data had the greatest uncertainty in our hands. Placing a chemically unreactive, EPR active standard in each reaction mixture could help alleviate this problem. Time-resolved Möss methods can be extremely powerful if excellent, nonoverlapping reference spectra of starting materials, products, and intermediates are available. All of the iron centers can be examined simultaneously. The problems associated with Möss arise from its extreme insensitivity. It takes millimolar solutions of proteins and several days for data collection of each time point.(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验