Baker S N, Lemon R N
Sobell Department of Neurophysiology, Institute of Neurology, London, UK.
J Neurosci Methods. 1995 Jul;59(2):175-81. doi: 10.1016/0165-0270(94)00180-o.
Studies on the motor system commonly use averages of rectified electromyogram (EMG) to measure muscular response. The assumption is usually made that this is a linear measure of response magnitude. It is shown here using a theoretical and experimental model that averages of rectified EMG can lead to non-linearities, which are of particular importance when considering the summation of two independent responses. When responses had a highly stereotyped waveform from trial to trial, so that averages of unrectified EMG revealed a deflection from zero, in measurements from averages of rectified EMG the size of a response to two stimuli delivered together was greater than the linear sum of the responses to each stimulus delivered alone. This deviation from linearity was greatest when two responses which were small relative to the ongoing background EMG activity were combined. The total response was then as much as twice as large as the linear sum of the individual component responses. Conversely, under conditions where responses were highly variable from trial to trial, resulting in no consistent deflection being seen in an average of unrectified EMG, the summed responses in rectified and averaged EMG were smaller than expected if summation were linear. This effect was most pronounced when both component responses were relatively large; the combined response tended asymptotically to approximately 70% of the linear sum of the component responses. A practical method is presented which allows prediction of the size of a response to two stimuli given together, when measured from averages of rectified EMG, on the assumption that they act independently.
对运动系统的研究通常使用整流肌电图(EMG)的平均值来测量肌肉反应。通常假定这是反应幅度的线性度量。本文通过理论和实验模型表明,整流EMG的平均值可能会导致非线性,这在考虑两个独立反应的总和时尤为重要。当每次试验的反应具有高度刻板的波形,以至于未整流EMG的平均值显示出从零的偏移时,在整流EMG平均值的测量中,对同时施加的两个刺激的反应大小大于对单独施加的每个刺激的反应的线性总和。当相对于持续的背景EMG活动较小的两个反应组合时,这种与线性的偏差最大。此时总反应高达各个成分反应线性总和的两倍。相反,在每次试验中反应高度可变的情况下,导致在未整流EMG的平均值中看不到一致的偏移,整流和平均EMG中的总和反应比如果总和是线性时预期的要小。当两个成分反应都相对较大时,这种效应最为明显;组合反应渐近地趋向于成分反应线性总和的约70%。本文提出了一种实用方法,在假定两个刺激独立起作用的情况下,当从整流EMG的平均值测量时,该方法可以预测对同时施加的两个刺激的反应大小。