Shen N, Zhu J
Department of Orthopedics, People's Hospital of Hainan Province, Haikou, People's Republic of China.
Microsurgery. 1995;16(8):552-5. doi: 10.1002/micr.1920160809.
In order to confirm the reliability of the sciatic functional index (SFI) in the rat, SFI, muscle strength, electrophysiological, and morphometric assessments were carried out from the 10th day to the sixth month after nerve injury or repair. The results showed that the SFI has a positive correlation with all tested indices of muscle strength, electrophysiology, and morphology (r = 0.925-0.996, P < 0.01 or P < 0.001). These results indicate that the SFI is a reliable index for evaluating rat sciatic nerve regeneration and can be widely used.
为了证实坐骨神经功能指数(SFI)在大鼠中的可靠性,在神经损伤或修复后的第10天至第六个月进行了SFI、肌肉力量、电生理和形态学评估。结果表明,SFI与肌肉力量、电生理和形态学的所有测试指标均呈正相关(r = 0.925 - 0.996,P < 0.01或P < 0.001)。这些结果表明,SFI是评估大鼠坐骨神经再生的可靠指标,可广泛应用。