• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Accuracy and reliability of weight change determinations in a model infant weighing less than 750 grams.

作者信息

Leamy V, Nalls S, Gallaher K J

机构信息

Department of Nursing, Cape Fear Valley Medical Center, Fayetteville, NC 28303, USA.

出版信息

J Perinatol. 1995 Sep-Oct;15(5):382-5.

PMID:8576751
Abstract

We designed a study to address the accuracy and reliability of the weighing process for tiny infants ( < 750 gm). A model was made with intravenous bags and stockinette and the following equipment was added: umbilical artery and venous catheters, endotracheal tube, pulse oximeter probe, electrodes, and orgastric tube. The models weight was changed in intervals of 2 to 43 gm and it was then weighed on two different types of scales. The measured weight on each scale was compared with the predicted weight (calculated as initial + added mass), and the mean absolute difference (MAD) was determined. All measurements were obtained by the same two nurses. For the bedside scale the MAD was 5 gm (range - 23 to + 10; n = 30). Similar results were obtained with a sling scale; the MAD was 3 gm (range - 13 to + 6 n = 30). The range of differences noted suggests that discrepancies between measurements may lead to a difference between weights that is in the range of 4% to 7% body weight. Interobserver variability was noted to affect the reliability of the weight determinations. When five experienced neonatal intensive care units nurses weighed the model the MAD was 9 gm (-33 to + 22; n = 15) and 6 gm (range - 11 to + 28; n = 15) for the bedside and sling scales, respectively. For the predicted weight, these discrepancies represent potential errors of 7.4% and 5.2%, respectively. These values are likely to underestimate the potential errors seen clinically inasmuch as we could not duplicate infant movement or anxiety of the person weighing the infant. These results should be considered when protocols are developed for weighing extremely small preterm infants.

摘要

相似文献

1
Accuracy and reliability of weight change determinations in a model infant weighing less than 750 grams.
J Perinatol. 1995 Sep-Oct;15(5):382-5.
2
Beneficial effects of breast milk in the neonatal intensive care unit on the developmental outcome of extremely low birth weight infants at 18 months of age.新生儿重症监护病房中母乳对极低出生体重儿18个月时发育结局的有益影响。
Pediatrics. 2006 Jul;118(1):e115-23. doi: 10.1542/peds.2005-2382.
3
Reliability of in-bed weighing procedures for critically ill infants.
Neonatal Netw. 1995 Aug;14(5):27-33; discussion 41.
4
[Weighing before and after feeding: an unreliable method for estimating milk intake in infants].喂奶前后称重:一种不可靠的估算婴儿奶量摄入的方法
Ned Tijdschr Geneeskd. 2007 Dec 8;151(49):2718-22.
5
Early hospital discharge of preterm very low birth weight infants.早产极低出生体重儿的早期出院
J Perinatol. 1997 Jan-Feb;17(1):29-32.
6
Accuracy of methods for calculating postnatal growth velocity for extremely low birth weight infants.极低出生体重儿出生后生长速度计算方法的准确性
Pediatrics. 2005 Dec;116(6):1466-73. doi: 10.1542/peds.2004-1699.
7
Infant physiologic and behavioral organization during swaddled versus unswaddled weighing.
J Perinatol. 1997 May-Jun;17(3):193-8.
8
Workload and short-term outcome of babies weighing 2,500 grams or more at birth admitted to the paediatric unit of the Rotunda Hospital.罗通达医院儿科收治的出生体重2500克及以上婴儿的工作量和短期预后
J Matern Fetal Neonatal Med. 2005 Feb;17(2):139-43. doi: 10.1080/14767050400029640.
9
Problems and management of low birth weight babies in an improvised neonatal unit of a developing country.发展中国家一个简易新生儿病房中低体重儿的问题与管理
Bull Int Pediatr Assoc. 1980 Jan;3(5):36-46.
10
Accuracy and precision of neonatal electronic incubator scales.
Neonatal Netw. 1995 Aug;14(5):35-9; discussion 41.