Reliability of in-bed weighing procedures for critically ill infants.

作者信息

Engstrom J L, Kavanaugh K, Meier P P, Boles E, Hernandez J, Wheeler D, Chuffo R

出版信息

Neonatal Netw. 1995 Aug;14(5):27-33; discussion 41.

PMID:7630331
Abstract

The purpose of this study was to describe the intra- and interexaminer reliability of weight measurements obtained from critically ill infants on an in-bed electronic scale. Weight measurements were obtained using the in-bed scale (Smart Model 35, Olympic Medical, Seattle, Washington) for 32 infants; 16 were in an incubator, and 16 were under a radiant warmer. Two nurses each obtained two weight measurements for each infant for three consecutive days, for a total of 96 data collection sessions. The nurses were blinded to their own and to the other nurse's weight measurements. The average mean absolute difference for individual nurses' weight measurements (interexaminer reliability) was 12.58 gm for weights obtained in the incubator and 19.19 gm for weights obtained under the radiant warmer. The average mean absolute difference for pairs of nurses' weight measurements (interexaminer reliability) was 14.29 gm for weights obtained in the incubator and 24.42 gm for weights obtained under the radiant warmer. The average mean absolute differences for weights obtained in the two bed types differed significantly for both intra- (Z = -2.46, p = .0141) and interexaminer (Z = -3.11, p = .0019) reliability. The number of pieces of equipment that had to be held during the weight measurement was weakly correlated with both the intra- (rs = .1878, p = .0091) and interexaminer (rs = .1600, p = .0266) mean absolute differences. These findings suggest that weight measurements of critically ill infants obtained using the Smart Model 35 in-bed electronic scale are sufficiently reliable for calculation of medication, parenteral fluid, blood replacement, and nutritional requirements.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Reliability of in-bed weighing procedures for critically ill infants.
Neonatal Netw. 1995 Aug;14(5):27-33; discussion 41.
2
Accuracy and precision of neonatal electronic incubator scales.
Neonatal Netw. 1995 Aug;14(5):35-9; discussion 41.
3
Reliability of three length measurement techniques in term infants.三种身长测量技术在足月儿中的可靠性
Pediatr Nurs. 1999 Jan-Feb;25(1):13-7.
4
Reliability of head circumference measurements in preterm infants.早产儿头围测量的可靠性
Pediatr Nurs. 1997 Sep-Oct;23(5):485-90.
5
Accuracy and reliability of weight change determinations in a model infant weighing less than 750 grams.
J Perinatol. 1995 Sep-Oct;15(5):382-5.
6
Energy metabolism and substrate utilization in low birth weight neonates under radiant warmers.辐射保暖箱下低出生体重新生儿的能量代谢与底物利用
Pediatrics. 1986 Sep;78(3):465-72.
7
A modified newborn intensive care unit environment may shorten hospital stay.改良的新生儿重症监护病房环境可能会缩短住院时间。
J Perinatol. 1994 Sep-Oct;14(5):422-7.
8
Effect of radiant warmer on transepidermal water loss (TEWL) and skin hydration in preterm infants.辐射保暖台对早产儿经皮水分丢失(TEWL)和皮肤水合作用的影响。
J Perinatol. 2004 Jun;24(6):372-5. doi: 10.1038/sj.jp.7211107.
9
Reliability of length measurements in full-term neonates.足月新生儿身长测量的可靠性
J Obstet Gynecol Neonatal Nurs. 1998 May-Jun;27(3):270-6. doi: 10.1111/j.1552-6909.1998.tb02649.x.
10
Reliability, technical error of measurements and validity of length and weight measurements for children under two years old in Malaysia.马来西亚两岁以下儿童身长和体重测量的可靠性、测量技术误差及有效性
Med J Malaysia. 2010 Jun;65 Suppl A:131-7.

引用本文的文献

1
Latin American consensus: children born small for gestational age.拉丁美洲共识:小于胎龄儿。
BMC Pediatr. 2011 Jul 19;11:66. doi: 10.1186/1471-2431-11-66.
2
Test weighing for term and premature infants is an accurate procedure.对足月儿和早产儿进行测试称重是一种准确的程序。
Arch Dis Child Fetal Neonatal Ed. 2007 Mar;92(2):F155-6. doi: 10.1136/adc.2006.113480.
3
A new growth chart for preterm babies: Babson and Benda's chart updated with recent data and a new format.早产婴儿的新生长图表:巴布森和本达图表采用最新数据及新格式进行了更新。
BMC Pediatr. 2003 Dec 16;3:13. doi: 10.1186/1471-2431-3-13.