Accuracy and precision of neonatal electronic incubator scales.

作者信息

Torrence C R, Horns K M, East C

出版信息

Neonatal Netw. 1995 Aug;14(5):35-9; discussion 41.

PMID:7630332
Abstract

Measurement of weight in the neonatal intensive care unit demands accuracy and precision. To date, however, no studies exist that independently document the accuracy of infant incubator bed scales. The purpose of this study is to evaluate the Airshields-Vickers Warm Weigh internally mounted incubator bed scale with foam and water mattresses using 500 gm and 1,500 gm standard weights to ascertain the precision of electronic bed scales and to evaluate the differences between nurse weighers. Two experienced neonatal nurses evaluated new incubator bed scales. Each nurse independently collected data and kept the results masked. Eight measurements were obtained from each incubator. Results indicated error beyond +/- 2 gm at 500 gm with the foam mattress and in both weight groups with the water mattress using the Technical Error Measurement (TEM) method. This indicates that the bed scales did not perform within the manufacturer's rated accuracy of +/- 2 gm at the smallest weights found in the clinical area. Weight errors were not judged to be clinically significant by a group of NNP experts.

摘要

相似文献

1
Accuracy and precision of neonatal electronic incubator scales.
Neonatal Netw. 1995 Aug;14(5):35-9; discussion 41.
2
Reliability of in-bed weighing procedures for critically ill infants.
Neonatal Netw. 1995 Aug;14(5):27-33; discussion 41.
3
Accuracy and reliability of weight change determinations in a model infant weighing less than 750 grams.
J Perinatol. 1995 Sep-Oct;15(5):382-5.
4
Optimizing care of ventilated infants by improving weighing accuracy on incubator scales.通过提高暖箱秤的称重准确性来优化通气婴儿的护理。
J Neonatal Perinatal Med. 2016;9(4):377-383. doi: 10.3233/NPM-161623.
5
A modified newborn intensive care unit environment may shorten hospital stay.改良的新生儿重症监护病房环境可能会缩短住院时间。
J Perinatol. 1994 Sep-Oct;14(5):422-7.
6
Cot-nursing using a heated, water-filled mattress and incubator care: a randomized clinical trial.使用加热的充水床垫进行母婴同室护理与保育箱护理:一项随机临床试验。
Acta Paediatr. 2004 Mar;93(3):350-5.
7
Neonatal response to control of noise inside the incubator.新生儿对培养箱内噪音控制的反应。
Pediatr Nurs. 2001 Nov-Dec;27(6):600-5.
8
The influence of equipment weights on neonatal daily weight measurements.
Neonatal Netw. 1999 Feb;18(1):33-6. doi: 10.1891/0730-0832.18.1.33.
9
Thermal stability and transition studies with a hybrid warming device for neonates.使用新生儿混合式保暖设备进行的热稳定性和转变研究。
J Perinatol. 2001 Apr-May;21(3):167-73. doi: 10.1038/sj.jp.7200513.
10
Using bed scales in the neonatal intensive care unit.
Neonatal Netw. 1991 Apr;9(7):37-40.