The purpose of the present study was to compare the Braun Plak Control (D7) and Philips HP 500 (MM) in their plaque removing efficacy. Furthermore the brushing force applied by the panelist on the brush-head with both these brushes was evaluated. For this study, 35 university students (non-dental) were selected. The study consisted of 3 experiments. Prior to each experiment, all subjects were asked to abstain from all oral hygiene procedures for at least 48 h. In Exp. I, the efficacy of toothbrushing was studied when one of the investigators brushed the teeth of the panellists. In Exp. II, the efficacy of the brushing was studied after the students had received a professional instruction. In Exp. III, the brushing force used during a single brushing exercise was evaluated. The available time for the brushing amounted to a total of 2 min per mouth. Dental plaque was evaluated by means of the Silness and Löe and Quigley and Hein plaque indices assessed at 6 sites per tooth. Results showed that both in Exp. I and Exp. II, the D7 removed significantly more plaque than the MM electric toothbrush. The plaque reduction assessed according to Silness and Löe in Exp. I was for the D7, 1.07 and for the MM, 0.78. In Exp. II, the reduction was 1.08 and 0.88, respectively. The results of Exp. III show that the mean brushing force was comparable for both brushes (D7 = 173 g, MM = 175 g). All 35 subjects were allowed to choose one electric toothbrush as compensation for their participation.(ABSTRACT TRUNCATED AT 250 WORDS)
本研究的目的是比较博朗 Plak Control(D7)和飞利浦 HP 500(MM)在去除牙菌斑功效方面的差异。此外,还评估了小组成员使用这两种牙刷时施加在刷头的刷牙力度。在本研究中,选取了35名大学生(非牙科专业)。该研究包括3个实验。在每个实验之前,要求所有受试者至少48小时内不进行任何口腔卫生护理。在实验I中,由一名研究人员为小组成员刷牙,研究刷牙效果。在实验II中,学生接受专业指导后再研究刷牙效果。在实验III中,评估单次刷牙过程中使用的刷牙力度。每口牙的刷牙总时长为2分钟。通过Silness和Löe以及Quigley和Hein牙菌斑指数在每颗牙的6个部位评估牙菌斑。结果显示,在实验I和实验II中,D7去除的牙菌斑均显著多于MM电动牙刷。根据Silness和Löe评估,实验I中D7的牙菌斑减少量为1.07,MM为0.78。在实验II中,减少量分别为1.08和0.88。实验III的结果表明,两种牙刷的平均刷牙力度相当(D7 = 173克,MM = 175克)。所有35名受试者可选择一款电动牙刷作为参与研究的报酬。(摘要截选至250词)