Juusola M, French A S
Department of Physiology and Biophysics, Dalhousie University, Halifax, Nova Scotia B3H 4H7, Canada.
Pflugers Arch. 1995 Nov;431(1):125-8. doi: 10.1007/BF00374385.
It is technically demanding to make intracellular measurements of mechanoreception in intact arthropod cuticular receptors. Here we introduce a method for recording mechanically induced electrical events in a class of spider mechanoreceptors using single electrode voltage- or current-clamp. A concave piece of cuticle containing a mechanosensitive lyriform slit organ was dissected free and fixed with wax onto a specially designed holder. This holder-cuticle complex, filled with spider saline, allowed displacement of the slit membrane from below while simultaneously recording intracellularly from neurons of the organ through a thin saline film. Extracellular ion concentrations could be changed and ion channel blockers could be applied to the bath. The method promises to allow the investigation of the ion channels responsible for mechanically transduced receptor signals and spike encoding.
在完整的节肢动物表皮感受器中进行机械感受的细胞内测量在技术上要求很高。在此,我们介绍一种使用单电极电压钳或电流钳记录一类蜘蛛机械感受器中机械诱导电活动的方法。将一块含有机械敏感琴形裂隙器官的凹形表皮解剖分离出来,并用蜡固定在一个特别设计的支架上。这个支架 - 表皮复合体充满蜘蛛生理盐水,能从下方使裂隙膜发生位移,同时通过一层薄盐水膜对器官中的神经元进行细胞内记录。细胞外离子浓度可以改变,离子通道阻滞剂可以加入浴液中。该方法有望用于研究负责机械转导受体信号和动作电位编码的离子通道。