Duvernoy O, Malm T, Ramström J, Bowald S
Department of Diagnostic Radiology, University Hospital, Uppsala, Sweden.
Thorac Cardiovasc Surg. 1995 Oct;43(5):271-4. doi: 10.1055/s-2007-1013226.
Biodegradable patches made of polyhydroxybutyrate (PHB) were recently shown to limit postoperative pericardial adhesions when inserted into the pericardium in sheep. The present study was carried out to evaluate the presence of post-operative retrosternal adhesions after cardiac surgery in patients operated on with the PHB patch compared with those operated on without the insertion of such a patch. 50 patients admitted for CABG and/or valvular replacement were randomised to treatment either with pericardial closure with a patch or with the pericardium left open. In 39 of these (19 with and 20 without a PHB patch) computerised tomography was carried out six and twenty-four months postoperatively. Computerised tomography indicated a lower incidence (p < 0.05) of postoperative adhesions between the patch and the cardiac surface in the patch group, compared with the corresponding area in the non-patch group. A reduction of patch size in 27% (p = 0.003) was also seen.