Wooley P H, Nasser S, Fitzgerald R H
Department of Internal Medicine, Wayne State University, Hutzel Hospital, Detroit, MI 48201, USA.
Clin Orthop Relat Res. 1996 May(326):63-70. doi: 10.1097/00003086-199605000-00008.
The etiology of aseptic loosening of prosthetic joint replacement components is unclear. Implant materials have been considered biologically inert, but recently studies indicate that inflammatory reactions directed against the implanted materials may contribute to aseptic loosening. Data suggesting a progression from a simple inflammatory reaction to complex immune responses against the biomaterials are reviewed. The cellular responses to particles of polymethylmethacrylate, ultrahigh molecular weight polyethylene, and alloys of cobalt-chromium and titanium were assayed in vitro to determine cell proliferation in patients with underlying diagnoses of osteoarthrosis, rheumatoid arthritis, and avascular necrosis who had joint replacement. Control populations were provided by patients with similar diagnoses who were preoperative surgical candidates. The underlying diagnoses did not seem to influence responses to particle stimulation. Elevated responses to both acrylic and cobalt-chromium were observed in patients with aseptically loosened prostheses. These findings suggest that the development of a cellular response to particulate debris may be significant in the pathogenesis of aseptic loosening.
人工关节置换部件无菌性松动的病因尚不清楚。植入材料一直被认为具有生物惰性,但最近的研究表明,针对植入材料的炎症反应可能导致无菌性松动。本文综述了从简单炎症反应发展为针对生物材料的复杂免疫反应的数据。对骨关节炎、类风湿性关节炎和无血管坏死患者进行关节置换后,在体外检测了细胞对聚甲基丙烯酸甲酯、超高分子量聚乙烯以及钴铬合金和钛合金颗粒的反应,以确定细胞增殖情况。对照组为具有相似诊断的术前手术候选患者。潜在诊断似乎并不影响对颗粒刺激的反应。在无菌性松动假体患者中观察到对丙烯酸和钴铬的反应增强。这些发现表明,细胞对颗粒碎片的反应在无菌性松动的发病机制中可能具有重要意义。