The effects of Carmeda Bioactive Surface on human blood components during simulated extracorporeal circulation.

作者信息

Korn R L, Fisher C A, Livingston E R, Stenach N, Fishman S J, Jeevanadam V, Addonizio V P

机构信息

Department of Surgery, Temple University Health Sciences Center, Philadelphia, PA 19140, USA.

出版信息

J Thorac Cardiovasc Surg. 1996 May;111(5):1073-84. doi: 10.1016/s0022-5223(96)70384-7.

Abstract

Postoperative morbidity after cardiopulmonary bypass most commonly manifests as bleeding diatheses or pulmonary dysfunction. The pathophysiology has been attributed to the activation of cellular and humoral components of blood after contact with an artificial surface. Development of a surface that would be nonthrombogenic and also would constitute a less potent inflammatory stimulus would therefore be beneficial. In the following experiments, we evaluated the heparin-bonded Carmeda Bioactive Surface (Medtronics Cardiopulmonary, Anaheim, Calif.) in an in vitro model of extracorporeal circulation at standard-dose heparin (5 U/ml), to examine the effects of the surface treatment on activation of blood elements, and at reduced-dose heparin (1 U/ml), to determine whether surface-bound heparin would serve as an effective anticoagulant. During the initial recirculation period, platelet counts in the Carmeda (n = 12) circuits were preserved at both doses of heparin and compared with control values (n = 12): At 5 U/ml, control 36% +/- 4% (mean +/- standard error of the mean) versus Carmeda 81% +/- 5%; at 1 U/ml, 43% +/- 3% versus 61% +/- 10%, expressed as a percent of baseline at 30 minutes, p < 0.05. Furthermore, plasma levels of platelet factor 4 and beta-thromboglobulin were significantly reduced in the Carmeda circuits throughout the experiment: At heparin 5 U/ml, 2500 +/- 340 ng/ml versus 604 +/- 191 ng/ml; at 1 U/ml, 2933 +/- 275 ng/ml versus 577 +/- 164 ng/ml of platelet factor 4 at 2 hours (p < 0.05). The pattern of beta-thromboglobulin release was similar, with effects more pronounced at the lower dose of heparin. Surface modification also reduced leukocyte depletion (p < 0.05) and release of elastase at both concentrations of heparin (5 U/ml, 0.72 +/- 0.29 ng/ml versus 0.33 +/- 0.23 ng/ml; 1 U/ml, 0.85 +/- 0.08 ng/ml versus 0.20 +/- 0.05 ng/ml, at 2 hours, p < 0.05). Moreover, as heparin concentration was reduced, Carmeda surface treatment significantly decreased generation of C3a des Arg (1 U/ml, 14,410 +/- 3558 ng/ml versus 3053 +/- 1039 ng/ml at 2 hours, p < 0.05). Although heparin bonding was originally intended to obviate the need for systemic heparinization, Carmeda treatment did not reduce fibrinopeptide A generation at the lower dose of heparin. In summary, Carmeda treatment failed to exhibit anticoagulant efficacy in this model; however, the data suggest that surface modification may have a role in ameliorating the typical inflammatory response initiated by blood contact with an artificial surface.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验